Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
18
matching recommendationsNAICS | 312111 | Soft Drink Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0805 # 10 Y:2009 | 10 | 2009 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,119 | $0 | Implemented |
UD0805 # 18 Y:2009 | 18 | 2009 | ISOLATE HOT OR COLD EQUIPMENT | $666 | $0 | Implemented |
UD0805 # 17 Y:2009 | 17 | 2009 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,423 | $0 | Not Implemented |
UD0805 # 16 Y:2009 | 16 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,428 | $1,000 | Implemented |
UD0805 # 15 Y:2009 | 15 | 2009 | OPTIMIZE PLANT POWER FACTOR | $1,903 | $5,000 | Not Implemented |
UD0805 # 14 Y:2009 | 14 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,965 | $0 | Implemented |
UD0805 # 13 Y:2009 | 13 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,689 | $0 | Implemented |
UD0805 # 12 Y:2009 | 12 | 2009 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $3,741 | $0 | Not Implemented |
UD0805 # 11 Y:2009 | 11 | 2009 | INSULATE BARE EQUIPMENT | $3,797 | $4,283 | Implemented |
UD0805 # 01 Y:2009 | 01 | 2009 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $39,022 | $12,000 | Not Implemented |
UD0805 # 09 Y:2009 | 09 | 2009 | REDUCE EXCESSIVE BOILER BLOWDOWN | $5,312 | $5,000 | Implemented |
UD0805 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,938 | $6,703 | Implemented |
UD0805 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,327 | $8,043 | Implemented |
UD0805 # 06 Y:2009 | 06 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,710 | $16,000 | Not Implemented |
UD0805 # 05 Y:2009 | 05 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,974 | $2,000 | Not Implemented |
UD0805 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,872 | $25,117 | Implemented |
UD0805 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,619 | $17,147 | Implemented |
UD0805 # 02 Y:2009 | 02 | 2009 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $21,769 | $25,000 | Not Implemented |