Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20
matching recommendationsNAICS | 3131 | Fiber, Yarn, and Thread Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0514 # 06 Y:2021 | 06 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,274 | $37,000 | Not Implemented |
LE0514 # 05 Y:2021 | 05 | 2021 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $3,549 | $13,500 | Not Implemented |
LE0514 # 04 Y:2021 | 04 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,301 | $19,000 | Not Implemented |
LE0514 # 03 Y:2021 | 03 | 2021 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $384 | $1,200 | Implemented |
LE0514 # 02 Y:2021 | 02 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,099 | $7,600 | Implemented |
LE0514 # 01 Y:2021 | 01 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,744 | $200 | Implemented |
LE0450 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,186 | $2,470 | Not Implemented |
LE0450 # 08 Y:2018 | 08 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,463 | $22,000 | Not Implemented |
LE0450 # 07 Y:2018 | 07 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,643 | $36,750 | Not Implemented |
LE0450 # 06 Y:2018 | 06 | 2018 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $3,038 | $8,000 | Not Implemented |
LE0450 # 04 Y:2018 | 04 | 2018 | INSTALL OCCUPANCY SENSORS | $1,023 | $1,625 | Not Implemented |
LE0450 # 03 Y:2018 | 03 | 2018 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,802 | $3,000 | Not Implemented |
LE0450 # 02 Y:2018 | 02 | 2018 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $16,243 | $8,000 | Not Implemented |
LE0450 # 01 Y:2018 | 01 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,167 | $1,000 | Not Implemented |
LE0192 # 01 Y:2004 | 01 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $22,723 | $5,000 | Not Implemented |
LE0192 # 06 Y:2004 | 06 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,219 | $0 | Implemented |
LE0192 # 05 Y:2004 | 05 | 2004 | INSULATE BARE EQUIPMENT | $2,750 | $8,250 | Not Implemented |
LE0192 # 04 Y:2004 | 04 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,128 | $1,084 | Implemented |
LE0192 # 03 Y:2004 | 03 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $9,668 | $3,000 | Not Implemented |
LE0192 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,677 | $0 | Implemented |