Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
79
matching recommendationsNAICS | 314120 | Curtain and Linen Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0921 # 05 Y:2019 | 05 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,972 | $32,568 | Not Implemented |
GT0921 # 04 Y:2019 | 04 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $947 | $3,500 | Implemented |
GT0921 # 03 Y:2019 | 03 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $543 | $847 | Not Implemented |
GT0921 # 02 Y:2019 | 02 | 2019 | INSTALL OCCUPANCY SENSORS | $1,446 | $1,974 | Not Implemented |
GT0921 # 01 Y:2019 | 01 | 2019 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $6,221 | $200 | Not Implemented |
NC0492 # 03 Y:2013 | 03 | 2013 | USE PHOTOCELL CONTROLS | $259 | $250 | Not Implemented |
NC0492 # 07 Y:2013 | 07 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $60 | $90 | Not Implemented |
NC0492 # 02 Y:2013 | 02 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,492 | $1,140 | Implemented |
NC0492 # 01 Y:2013 | 01 | 2013 | INSTALL OCCUPANCY SENSORS | $8,471 | $13,495 | Not Implemented |
NC0492 # 05 Y:2013 | 05 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $688 | $0 | Implemented |
NC0492 # 06 Y:2013 | 06 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $20,838 | $12,000 | Not Implemented |
NC0492 # 04 Y:2013 | 04 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,869 | $100 | Not Implemented |
OK0792 # 08 Y:2010 | 08 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $304 | $902 | Implemented |
OK0792 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $733 | $2,755 | Implemented |
OK0792 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $959 | $750 | Implemented |
OK0792 # 11 Y:2010 | 11 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,037 | $78,057 | Not Implemented |
OK0792 # 09 Y:2010 | 09 | 2010 | INSULATE BARE EQUIPMENT | $156 | $143 | Not Implemented |
OK0792 # 07 Y:2010 | 07 | 2010 | OPTIMIZE PLANT POWER FACTOR | $1,160 | $11,630 | Not Implemented |
OK0792 # 10 Y:2010 | 10 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $6,203 | $109,200 | Not Implemented |
OK0792 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $469 | $275 | Implemented |
OK0792 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,607 | $8,168 | Not Implemented |
OK0792 # 01 Y:2010 | 01 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,543 | $3,114 | Implemented |
OK0792 # 06 Y:2010 | 06 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $741 | $644 | Implemented |
WV0393 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $69,642 | $143,500 | Implemented |
WV0393 # 13 Y:2009 | 13 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $370 | $0 | Implemented |