IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

154

matching recommendations
Reset
NAICS 314999 All Other Miscellaneous Textile Product Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0674 # 01 Y:2015 01 2015 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $23,350 $24,500 Not Implemented
AM0674 # 04 Y:2015 04 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,420 $5 Not Implemented
AM0674 # 05 Y:2015 05 2015 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,185 $500 Implemented
AM0674 # 06 Y:2015 06 2015 INSULATE FEEDWATER TANK $950 $140 Not Implemented
AM0674 # 07 Y:2015 07 2015 INSTALL SKYLIGHTS $625 $970 Not Implemented
AM0674 # 08 Y:2015 08 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $550 $275 Implemented
AM0674 # 09 Y:2015 09 2015 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $430 $0 Not Implemented
SF0456 # 02 Y:2014 02 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,324 $80 Implemented
SF0456 # 06 Y:2014 06 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,511 $18,537 Implemented
SF0456 # 01 Y:2014 01 2014 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $8,140 $0 Implemented
SF0456 # 05 Y:2014 05 2014 INSULATE BARE EQUIPMENT $502 $638 Implemented
SF0456 # 04 Y:2014 04 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $114 $127 Implemented
SF0456 # 03 Y:2014 03 2014 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $883 $327 Implemented
DL0115 # 01 Y:2013 01 2013 TURN OFF EQUIPMENT WHEN NOT IN USE $3,106 $0 Implemented
DL0115 # 02 Y:2013 02 2013 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $2,900 $350 Implemented
DL0115 # 03 Y:2013 03 2013 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,400 $16,000 Not Implemented
DL0115 # 04 Y:2013 04 2013 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $4,460 $29,700 Implemented
DL0115 # 05 Y:2013 05 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,140 $3,380 Not Implemented
DL0115 # 06 Y:2013 06 2013 INSTALL OCCUPANCY SENSORS $640 $600 Implemented
DL0115 # 07 Y:2013 07 2013 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $830 $6,000 Not Implemented
DL0115 # 08 Y:2013 08 2013 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $1,405 $2,110 Not Implemented
DL0115 # 09 Y:2013 09 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,710 $8,485 Implemented
DL0115 # 10 Y:2013 10 2013 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,270 $0 Implemented
DL0083 # 09 Y:2012 09 2012 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $1,190 $150 Not Implemented
DL0083 # 08 Y:2012 08 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,964 $28,300 Not Implemented