Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
398
matching recommendationsNAICS | 315 | Apparel Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0474 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,078 | $1,180 | Implemented |
NC0474 # 04 Y:2013 | 04 | 2013 | USE PHOTOCELL CONTROLS | $3,817 | $7,000 | Not Implemented |
NC0474 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $1,019 | $3,470 | Implemented |
NC0474 # 06 Y:2013 | 06 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,431 | $1,000 | Implemented |
NC0474 # 07 Y:2013 | 07 | 2013 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $11,656 | $25,000 | Not Implemented |
NC0474 # 08 Y:2013 | 08 | 2013 | REPAIR OR REPLACE STEAM TRAPS | $13,419 | $5,700 | Implemented |
NC0474 # 09 Y:2013 | 09 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,672 | $100 | Implemented |
OK0824 # 01 Y:2012 | 01 | 2012 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $17,721 | $31,152 | Not Implemented |
OK0824 # 02 Y:2012 | 02 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $21,096 | $22,080 | Not Implemented |
OK0824 # 03 Y:2012 | 03 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $9,127 | $23,400 | Not Implemented |
OK0824 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $2,183 | $8,237 | Not Implemented |
OK0824 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,772 | $8,055 | Implemented |
OK0824 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $787 | $4,095 | Implemented |
OK0824 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $687 | $1,691 | Implemented |
OK0824 # 08 Y:2012 | 08 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $6,045 | $162,500 | Implemented |
OK0824 # 09 Y:2012 | 09 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,249 | $461 | Not Implemented |
UA0067 # 01 Y:2011 | 01 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $7,432 | $120 | Implemented |
UA0067 # 02 Y:2011 | 02 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,859 | $480 | Implemented |
UA0067 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $726 | $1,100 | Implemented |
UA0067 # 04 Y:2011 | 04 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $6,396 | $9,456 | Not Implemented |
MI0202 # 01 Y:2011 | 01 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $24,647 | $9,000 | Implemented |
MI0202 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,531 | $62,700 | Implemented |
MI0202 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,679 | $1,320 | Implemented |
MI0202 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $2,481 | $6,700 | Not Implemented |
MI0202 # 05 Y:2011 | 05 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,001 | $1,980 | Not Implemented |