Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
449
matching recommendationsNAICS | 32111 | Sawmills and Wood Preservation |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NL0004 # 06 Y:2017 | 06 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $823 | $2,300 | Implemented |
NL0004 # 04 Y:2017 | 04 | 2017 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $6,396 | $1,100 | Implemented |
NL0004 # 03 Y:2017 | 03 | 2017 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $30,789 | $30,000 | Implemented |
NL0004 # 02 Y:2017 | 02 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $65,107 | $300,000 | Implemented |
NL0004 # 01 Y:2017 | 01 | 2017 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $93,000 | $125,000 | Implemented |
AM0728 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,680 | $20,300 | Implemented |
AM0728 # 02 Y:2017 | 02 | 2017 | OPTIMIZE PLANT POWER FACTOR | $8,480 | $5,420 | Implemented |
AM0728 # 03 Y:2017 | 03 | 2017 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $41,700 | $4,000 | Implemented |
AM0728 # 04 Y:2017 | 04 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,530 | $1,000 | Implemented |
AM0728 # 05 Y:2017 | 05 | 2017 | USE PHOTOCELL CONTROLS | $2,740 | $140 | Implemented |
AM0728 # 06 Y:2017 | 06 | 2017 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,100 | $1,070 | Implemented |
AM0728 # 07 Y:2017 | 07 | 2017 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,250 | $1,000 | Implemented |
AM0728 # 08 Y:2017 | 08 | 2017 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $11,310 | $4,370 | Implemented |
AM0728 # 09 Y:2017 | 09 | 2017 | PAY UTILITY BILLS ON TIME | $676 | $0 | Implemented |
AM0728 # 10 Y:2017 | 10 | 2017 | USE SYNTHETIC LUBRICANT | $386 | $0 | Implemented |
OKO952 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,312 | $0 | Implemented |
OKO952 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,284 | $6,222 | Implemented |
OKO952 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,021 | $29,085 | Implemented |
OKO952 # 01 Y:2016 | 01 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $39,072 | $32,000 | Implemented |
OR0676 # 03 Y:2016 | 03 | 2016 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $216,607 | $80,000 | Implemented |
OR0676 # 04 Y:2016 | 04 | 2016 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $11,774 | $7,200 | Implemented |
OR0676 # 05 Y:2016 | 05 | 2016 | ADD AREA LIGHTING SWITCHES | $1,356 | $1,062 | Implemented |
OR0676 # 06 Y:2016 | 06 | 2016 | INSULATE BARE EQUIPMENT | $2,884 | $6,584 | Implemented |
BS0081 # 06 Y:2016 | 06 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $401 | $550 | Implemented |
BS0081 # 05 Y:2016 | 05 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $462 | $15 | Implemented |