Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
18
matching recommendationsNAICS | 321991 | Manufactured Home (Mobile Home) Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0146 # 04 Y:2014 | 04 | 2014 | BURN WASTE PAPER FOR HEAT | $5,426 | $19,895 | Not Implemented |
TT0146 # 03 Y:2014 | 03 | 2014 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $1,898 | $24,450 | Not Implemented |
TT0146 # 02 Y:2014 | 02 | 2014 | INSTALL SKYLIGHTS | $2,012 | $14,000 | Not Implemented |
TT0146 # 01 Y:2014 | 01 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $1,943 | $822 | Implemented |
TT0137 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,360 | $822 | Implemented |
TT0137 # 05 Y:2014 | 05 | 2014 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $26,063 | $4,272 | Implemented |
TT0137 # 04 Y:2014 | 04 | 2014 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,191 | $5,200 | Not Implemented |
TT0137 # 03 Y:2014 | 03 | 2014 | INSTALL SKYLIGHTS | $8,488 | $33,000 | Implemented |
TT0137 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,154 | $6,230 | Implemented |
NC0508 # 01 Y:2014 | 01 | 2014 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $9,684 | $2,200 | Implemented |
NC0508 # 09 Y:2014 | 09 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $1,128 | $4,256 | Not Implemented |
NC0508 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $359 | $574 | Not Implemented |
NC0508 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,026 | $240 | Implemented |
NC0508 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $520 | $4,006 | Not Implemented |
NC0508 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,695 | $28,977 | Implemented |
NC0508 # 04 Y:2014 | 04 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,952 | $2,300 | Implemented |
NC0508 # 03 Y:2014 | 03 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,274 | $1,950 | Not Implemented |
NC0508 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $865 | $100 | Implemented |