Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
294
matching recommendationsNAICS | 321999 | All Other Miscellaneous Wood Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0345 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $413 | $725 | Not Implemented |
BD0345 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $324 | $550 | Implemented |
BD0345 # 04 Y:2008 | 04 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $330 | $300 | Implemented |
BD0345 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,343 | $1,000 | Implemented |
BD0345 # 06 Y:2008 | 06 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $3,422 | $10,592 | Implemented |
BD0345 # 07 Y:2008 | 07 | 2008 | USE SYNTHETIC LUBRICANT | $72 | $100 | Implemented |
AM0538 # 01 Y:2008 | 01 | 2008 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $192,300 | $174,034 | Not Implemented |
AM0538 # 02 Y:2008 | 02 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $171,000 | $5,000 | Implemented |
AM0538 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $41,905 | $105,000 | Implemented |
AM0538 # 04 Y:2008 | 04 | 2008 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $2,200,000 | $6,600,000 | Implemented |
AM0538 # 05 Y:2008 | 05 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,200 | $0 | Not Implemented |
AM0538 # 06 Y:2008 | 06 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,770 | $1,120 | Implemented |
AM0538 # 07 Y:2008 | 07 | 2008 | USE SYNTHETIC LUBRICANT | $1,045 | $0 | Not Implemented |
LM0114 # 01 Y:2006 | 01 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,544 | $0 | Implemented |
LM0114 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,286 | $9,409 | Not Implemented |
LM0114 # 03 Y:2006 | 03 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $811 | $0 | Implemented |
LM0114 # 04 Y:2006 | 04 | 2006 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $175,670 | $14,400 | Not Implemented |
LM0114 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,671 | $200 | Implemented |
BD0310 # 01 Y:2006 | 01 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $4,173 | $2 | Implemented |
BD0310 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,537 | $600 | Implemented |
BD0310 # 03 Y:2006 | 03 | 2006 | USE SYNTHETIC LUBRICANT | $805 | $300 | Implemented |
BD0310 # 04 Y:2006 | 04 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $577 | $0 | Not Implemented |
BD0310 # 05 Y:2006 | 05 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $267 | $500 | Implemented |
BD0310 # 06 Y:2006 | 06 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,368 | $90 | Implemented |
BD0310 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $288 | $225 | Not Implemented |