Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17
matching recommendationsNAICS | 32211 | Pulp Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0580 # 06 Y:2019 | 06 | 2019 | REPAIR OR REPLACE STEAM TRAPS | $1,791 | $5,731 | Implemented |
WV0580 # 05 Y:2019 | 05 | 2019 | INSULATE BARE EQUIPMENT | $2,238 | $2,550 | Implemented |
WV0580 # 04 Y:2019 | 04 | 2019 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,437 | $15,360 | Implemented |
WV0580 # 03 Y:2019 | 03 | 2019 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $52,590 | $160,314 | Not Implemented |
WV0580 # 02 Y:2019 | 02 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $143,962 | $6,000 | Implemented |
WV0580 # 01 Y:2019 | 01 | 2019 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $265,061 | $31,000 | Not Implemented |
WV0365 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,552 | $0 | Implemented |
WV0365 # 11 Y:2007 | 11 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,863 | $2,514 | Implemented |
WV0365 # 10 Y:2007 | 10 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,435 | $0 | Implemented |
WV0365 # 01 Y:2007 | 01 | 2007 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $1,979,852 | $607,600 | Not Implemented |
WV0365 # 08 Y:2007 | 08 | 2007 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,649 | $9,450 | Implemented |
WV0365 # 07 Y:2007 | 07 | 2007 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $9,063 | $39,000 | Not Implemented |
WV0365 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $17,614 | $8,565 | Implemented |
WV0365 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,685 | $75,450 | Implemented |
WV0365 # 04 Y:2007 | 04 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $75,759 | $228,975 | Implemented |
WV0365 # 03 Y:2007 | 03 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $87,247 | $12,756 | Not Implemented |
WV0365 # 02 Y:2007 | 02 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $279,065 | $31,300 | Not Implemented |