IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

453

matching recommendations
Reset
NAICS 322121 Paper (except Newsprint) Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0473 # 07 Y:2016 07 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,273 $25 Not Implemented
BD0473 # 06 Y:2016 06 2016 USE SYNTHETIC LUBRICANT $2,870 $1,000 Implemented
BD0473 # 05 Y:2016 05 2016 ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION $3,820 $15,000 Not Implemented
BD0473 # 04 Y:2016 04 2016 INSTALL OCCUPANCY SENSORS $4,714 $1,650 Not Implemented
BD0473 # 03 Y:2016 03 2016 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $21,188 $60,260 Not Implemented
BD0473 # 02 Y:2016 02 2016 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $28,176 $50,000 Not Implemented
BD0473 # 01 Y:2016 01 2016 REPAIR OR REPLACE STEAM TRAPS $80,322 $10,300 Implemented
BD0473 # 12 Y:2016 12 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $456 $400 Implemented
UA0151 # 01 Y:2015 01 2015 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $107,877 $42,000 Implemented
UA0151 # 02 Y:2015 02 2015 INCREASE AMOUNT OF CONDENSATE RETURNED $48,953 $110,000 Implemented
UA0151 # 03 Y:2015 03 2015 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $182,046 $500,000 Not Implemented
UA0151 # 04 Y:2015 04 2015 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $25,377 $93,550 Not Implemented
UA0151 # 05 Y:2015 05 2015 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $23,156 $85,365 Not Implemented
MA0727 # 05 Y:2014 05 2014 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,122 $1,500 Implemented
MA0727 # 04 Y:2014 04 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $2,761 $1,598 Not Implemented
MA0727 # 03 Y:2014 03 2014 PAY UTILITY BILLS ON TIME $6,481 $500 Implemented
MA0727 # 02 Y:2014 02 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $52,084 $127,730 Not Implemented
MA0727 # 01 Y:2014 01 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $82,693 $153,000 Not Implemented
MA0725 # 12 Y:2014 12 2014 INSULATE BARE EQUIPMENT $3,366 $30,760 Implemented
MA0725 # 11 Y:2014 11 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,444 $10,200 Not Implemented
MA0725 # 10 Y:2014 10 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,314 $10,600 Implemented
MA0725 # 09 Y:2014 09 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,970 $13,450 Not Implemented
MA0725 # 08 Y:2014 08 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,977 $12,270 Implemented
MA0725 # 07 Y:2014 07 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,381 $15,200 Not Implemented
MA0725 # 06 Y:2014 06 2014 UPGRADE CONTROLS ON COMPRESSORS $23,788 $9,000 Implemented