Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
481
matching recommendationsNAICS | 32222 | Paper Bag and Coated and Treated Paper Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0381 # 06 Y:2025 | 06 | 2025 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $318,110 | $818,754 | n/a |
MZ0381 # 02 Y:2025 | 02 | 2025 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $24,783 | $28,280 | n/a |
MZ0381 # 04 Y:2025 | 04 | 2025 | USE SOLAR HEAT TO MAKE ELECTRICTY | $428,798 | $4,387,498 | n/a |
MZ0381 # 03 Y:2025 | 03 | 2025 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,828 | $0 | n/a |
MZ0381 # 01 Y:2025 | 01 | 2025 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,000 | $19,875 | n/a |
MZ0381 # 05 Y:2025 | 05 | 2025 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $87,568 | $395,000 | n/a |
MZ0380 # 06 Y:2025 | 06 | 2025 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $81,337 | $387,626 | n/a |
MZ0380 # 11 Y:2025 | 11 | 2025 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $53,306 | $145,600 | n/a |
MZ0380 # 03 Y:2025 | 03 | 2025 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $2,269 | $500 | n/a |
MZ0380 # 09 Y:2025 | 09 | 2025 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $53,986 | $195,000 | n/a |
MZ0380 # 08 Y:2025 | 08 | 2025 | INSTALL OCCUPANCY SENSORS | $4,713 | $2,400 | n/a |
MZ0380 # 07 Y:2025 | 07 | 2025 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,164 | $0 | n/a |
MZ0380 # 02 Y:2025 | 02 | 2025 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $106,086 | $31,591 | n/a |
MZ0380 # 01 Y:2025 | 01 | 2025 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $105,308 | $41,000 | n/a |
MZ0380 # 05 Y:2025 | 05 | 2025 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $10,506 | $19,860 | n/a |
MZ0380 # 04 Y:2025 | 04 | 2025 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $11,856 | $3,000 | n/a |
MZ0380 # 10 Y:2025 | 10 | 2025 | USE SOLAR HEAT TO MAKE ELECTRICTY | $37,784 | $447,535 | n/a |
LE0600 # 03 Y:2025 | 03 | 2025 | INSTALL OCCUPANCY SENSORS | $6,925 | $420 | n/a |
LE0600 # 09 Y:2025 | 09 | 2025 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,420 | $4,000 | n/a |
LE0600 # 01 Y:2025 | 01 | 2025 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,082 | $0 | n/a |
LE0600 # 10 Y:2025 | 10 | 2025 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,545 | $9,511 | n/a |
LE0600 # 08 Y:2025 | 08 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,572 | $26,690 | n/a |
LE0600 # 07 Y:2025 | 07 | 2025 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,555 | $7,500 | n/a |
LE0600 # 05 Y:2025 | 05 | 2025 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,757 | $2,500 | n/a |
LE0600 # 06 Y:2025 | 06 | 2025 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $14,877 | $20,000 | n/a |