Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21
matching recommendationsNAICS | 32223 | Stationery Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0427 # 06 Y:2017 | 06 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,186 | $5,500 | Not Implemented |
LE0427 # 05 Y:2017 | 05 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,580 | $3,500 | Implemented |
LE0427 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,621 | $5,775 | Implemented |
LE0427 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,823 | $14,438 | Implemented |
LE0427 # 02 Y:2017 | 02 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,286 | $1,200 | Implemented |
LE0427 # 01 Y:2017 | 01 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,735 | $1,000 | Implemented |
LE0219 # 02 Y:2005 | 02 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $912 | $100 | Implemented |
LE0219 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,910 | $14,173 | Not Implemented |
LE0219 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $1,305 | $675 | Not Implemented |
LE0219 # 04 Y:2005 | 04 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $129 | $100 | Implemented |
LE0219 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $352 | $80 | Implemented |
LE0219 # 01 Y:2005 | 01 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,717 | $1,500 | Not Implemented |
LE0191 # 01 Y:2004 | 01 | 2004 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $19,209 | $8,000 | Not Implemented |
LE0191 # 09 Y:2004 | 09 | 2004 | INSTALL OCCUPANCY SENSORS | $719 | $750 | Not Implemented |
LE0191 # 08 Y:2004 | 08 | 2004 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $581 | $0 | Implemented |
LE0191 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,161 | $200 | Implemented |
LE0191 # 06 Y:2004 | 06 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,195 | $0 | Not Implemented |
LE0191 # 05 Y:2004 | 05 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $4,530 | $750 | Implemented |
LE0191 # 04 Y:2004 | 04 | 2004 | OPTIMIZE PLANT POWER FACTOR | $8,221 | $2,500 | Implemented |
LE0191 # 03 Y:2004 | 03 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $9,591 | $3,200 | Not Implemented |
LE0191 # 02 Y:2004 | 02 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $13,043 | $2,500 | Implemented |