Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21
matching recommendationsNAICS | 32223 | Stationery Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0219 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,910 | $14,173 | Not Implemented |
LE0219 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $1,305 | $675 | Not Implemented |
LE0219 # 04 Y:2005 | 04 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $129 | $100 | Implemented |
LE0219 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $352 | $80 | Implemented |
LE0219 # 02 Y:2005 | 02 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $912 | $100 | Implemented |
LE0219 # 01 Y:2005 | 01 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,717 | $1,500 | Not Implemented |
LE0213 # 02 Y:2005 | 02 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $22,533 | $6,000 | Implemented |
LE0213 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,210 | $53,880 | Implemented |
LE0213 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,384 | $200 | Implemented |
LE0213 # 06 Y:2005 | 06 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,694 | $2,000 | Implemented |
LE0213 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,792 | $1,000 | Implemented |
LE0213 # 04 Y:2005 | 04 | 2005 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $5,279 | $368 | Not Implemented |
LE0213 # 03 Y:2005 | 03 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,703 | $25,000 | Not Implemented |
LE0213 # 01 Y:2005 | 01 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $24,825 | $1,344 | Implemented |
OK0707 # 01 Y:2005 | 01 | 2005 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $4,316 | $7,739 | Not Implemented |
OK0707 # 02 Y:2005 | 02 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,571 | $25,675 | Implemented |
OK0707 # 03 Y:2005 | 03 | 2005 | INSTALL SET-BACK TIMERS | $4,532 | $1,380 | Not Implemented |
OK0707 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,916 | $617 | Not Implemented |
OK0707 # 05 Y:2005 | 05 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,639 | $6,750 | Implemented |
OK0707 # 06 Y:2005 | 06 | 2005 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,173 | $6,405 | Not Implemented |
OK0707 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $594 | $626 | Not Implemented |