Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,874

matching recommendations
Reset
NAICS 32311 Printing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1910 # 09 Y:2019 09 2019 REDUCE FLUID FLOW RATES $1,484 $1,900 Implemented
UK1910 # 10 Y:2019 10 2019 PREHEAT COMBUSTION AIR WITH WASTE HEAT $1,344 $2,838 Implemented
UK1910 # 11 Y:2019 11 2019 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,251 $1,000 Implemented
UK1910 # 12 Y:2019 12 2019 OPTIMIZE PLANT POWER FACTOR $13,040 $16,170 Implemented
UK1910 # 13 Y:2019 13 2019 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $7,015 $0 Implemented
SU0482 # 01 Y:2019 01 2019 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,458 $0 Not Implemented
SU0482 # 02 Y:2019 02 2019 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $2,702 $0 Implemented
SU0482 # 03 Y:2019 03 2019 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,292 $80 Not Implemented
SU0482 # 04 Y:2019 04 2019 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $260 $0 Implemented
SU0482 # 05 Y:2019 05 2019 INSTALL OCCUPANCY SENSORS $84 $176 Not Implemented
MA0802 # 01 Y:2019 01 2019 RECOVER WASTE HEAT FROM EQUIPMENT $109,879 $475,000 Not Implemented
MA0802 # 02 Y:2019 02 2019 TURN OFF EQUIPMENT WHEN NOT IN USE $29,299 $2,830 Implemented
MA0802 # 03 Y:2019 03 2019 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $14,618 $47,380 Not Implemented
MA0802 # 04 Y:2019 04 2019 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,964 $22,750 Implemented
MA0802 # 05 Y:2019 05 2019 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,748 $13,000 Not Implemented
TT0222 # 01 Y:2019 01 2019 INSTALL OCCUPANCY SENSORS $7,958 $4,620 Not Implemented
TT0222 # 02 Y:2019 02 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,993 $16,370 Implemented
TT0222 # 03 Y:2019 03 2019 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $5,547 $2,050 Not Implemented
TT0222 # 04 Y:2019 04 2019 TURN OFF EQUIPMENT WHEN NOT IN USE $857 $440 Implemented
SD0582 # 01 Y:2019 01 2019 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $24,520 $35,000 Implemented
SD0582 # 02 Y:2019 02 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,455 $8,348 Implemented
SD0582 # 03 Y:2019 03 2019 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,534 $9,736 Implemented
SD0582 # 04 Y:2019 04 2019 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $342 $760 Implemented
SF0540 # 01 Y:2019 01 2019 USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS $3,623 $0 Implemented
SF0540 # 02 Y:2019 02 2019 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,827 $0 Implemented