Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
84
matching recommendationsNAICS | 323111 | Commercial Printing (except Screen and Books) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0148 # 07 Y:2019 | 07 | 2019 | USE RADIANT HEATER FOR SPOT HEATING | $3,041 | $2,800 | Not Implemented |
WM0148 # 14 Y:2019 | 14 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $805 | $1,664 | Implemented |
WM0148 # 15 Y:2019 | 15 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $741 | $970 | Not Implemented |
WM0148 # 01 Y:2019 | 01 | 2019 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $23,863 | $21,000 | Not Implemented |
WM0148 # 02 Y:2019 | 02 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $21,662 | $106,000 | Not Implemented |
WM0148 # 03 Y:2019 | 03 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,757 | $0 | Not Implemented |
WM0148 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,118 | $5,000 | Implemented |
WM0148 # 13 Y:2019 | 13 | 2019 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,087 | $0 | Not Implemented |
WM0148 # 11 Y:2019 | 11 | 2019 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,396 | $0 | Implemented |
WM0148 # 16 Y:2019 | 16 | 2019 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $617 | $1,175 | Not Implemented |
WM0148 # 06 Y:2019 | 06 | 2019 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $3,158 | $1,365 | Implemented |
WM0148 # 05 Y:2019 | 05 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,478 | $8,880 | Not Implemented |
WM0148 # 08 Y:2019 | 08 | 2019 | INSTALL OCCUPANCY SENSORS | $1,718 | $2,325 | Not Implemented |
WM0148 # 09 Y:2019 | 09 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,616 | $3,900 | Not Implemented |
WM0148 # 10 Y:2019 | 10 | 2019 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,409 | $1,750 | Not Implemented |
WM0148 # 12 Y:2019 | 12 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,320 | $2,340 | Not Implemented |
UK1910 # 04 Y:2019 | 04 | 2019 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $4,283 | $0 | Implemented |
UK1910 # 09 Y:2019 | 09 | 2019 | REDUCE FLUID FLOW RATES | $1,484 | $1,900 | Implemented |
UK1910 # 08 Y:2019 | 08 | 2019 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,365 | $3,625 | Implemented |
UK1910 # 07 Y:2019 | 07 | 2019 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $838 | $350 | Implemented |
UK1910 # 06 Y:2019 | 06 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $569 | $300 | Implemented |
UK1910 # 05 Y:2019 | 05 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $65,342 | $110,141 | Implemented |
UK1910 # 11 Y:2019 | 11 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,251 | $1,000 | Implemented |
UK1910 # 10 Y:2019 | 10 | 2019 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,344 | $2,838 | Implemented |
UK1910 # 01 Y:2019 | 01 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,415 | $2,477 | Implemented |