Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
125
matching recommendationsNAICS | 323113 | Commercial Screen Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0022 # 03 Y:2013 | 03 | 2013 | INSULATE BARE EQUIPMENT | $2,744 | $2,303 | Implemented |
DL0051 # 01 Y:2010 | 01 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,124 | $0 | Implemented |
DL0051 # 02 Y:2010 | 02 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $573 | $0 | Implemented |
DL0051 # 03 Y:2010 | 03 | 2010 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $940 | $30 | Implemented |
DL0051 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,500 | $100 | Implemented |
DL0051 # 05 Y:2010 | 05 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $860 | $150 | Not Implemented |
DL0051 # 06 Y:2010 | 06 | 2010 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $4,250 | $960 | Not Implemented |
DL0051 # 07 Y:2010 | 07 | 2010 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $4,473 | $3,840 | Not Implemented |
DL0051 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,720 | $20,796 | Not Implemented |
DL0051 # 09 Y:2010 | 09 | 2010 | REPLACE BOILER | $6,600 | $16,743 | Implemented |
MZ0039 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $48,883 | $510,446 | Implemented |
MZ0039 # 02 Y:2009 | 02 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $12,294 | $8,400 | Implemented |
MZ0039 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $840 | $850 | Implemented |
MZ0039 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $22,863 | $0 | Implemented |
MZ0039 # 05 Y:2009 | 05 | 2009 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $15,679 | $18,600 | Implemented |
WV0363 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,046 | $8,058 | Implemented |
WV0363 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,878 | $8,630 | Implemented |
WV0363 # 03 Y:2007 | 03 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $12,259 | $122,100 | Implemented |
WV0363 # 04 Y:2007 | 04 | 2007 | COMBINE UTILITY METERS | $11,248 | $12,500 | Not Implemented |
WV0363 # 05 Y:2007 | 05 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,928 | $511 | Implemented |
WV0363 # 06 Y:2007 | 06 | 2007 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,228 | $9,945 | Implemented |
WV0363 # 07 Y:2007 | 07 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $7,036 | $984 | Not Implemented |
WV0363 # 08 Y:2007 | 08 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,820 | $183 | Implemented |
WV0363 # 09 Y:2007 | 09 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $3,839 | $1,105 | Not Implemented |
WV0363 # 10 Y:2007 | 10 | 2007 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $2,611 | $4,505 | Implemented |