IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,556

matching recommendations
Reset
NAICS 325 Chemical Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0382 # 02 Y:2008 02 2008 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,305 $8,000 Not Implemented
NC0382 # 03 Y:2008 03 2008 RECOVER WASTE HEAT FROM EQUIPMENT $11,864 $6,150 Not Implemented
NC0382 # 04 Y:2008 04 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,333 $100 Implemented
NC0382 # 05 Y:2008 05 2008 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,226 $0 Implemented
NC0382 # 06 Y:2008 06 2008 DEVELOP A REPAIR/REPLACE POLICY $1,644 $2,483 Implemented
NC0382 # 07 Y:2008 07 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,264 $4,408 Implemented
NC0383 # 01 Y:2008 01 2008 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $16,582 $1,000 Implemented
NC0383 # 02 Y:2008 02 2008 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $38,474 $0 Implemented
NC0383 # 03 Y:2008 03 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $42,558 $50,000 Implemented
NC0383 # 04 Y:2008 04 2008 INCREASE AMOUNT OF CONDENSATE RETURNED $19,037 $30,000 Not Implemented
NC0383 # 05 Y:2008 05 2008 INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK $4,551 $10,000 Implemented
NC0383 # 06 Y:2008 06 2008 UTILIZE A LESS EXPENSIVE COOLING METHOD $4,245 $20,000 Not Implemented
NC0383 # 07 Y:2008 07 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,848 $50 Not Implemented
NC0383 # 08 Y:2008 08 2008 RECOVER WASTE HEAT FROM EQUIPMENT $11,043 $6,150 Not Implemented
NC0383 # 09 Y:2008 09 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,623 $100 Implemented
NC0383 # 10 Y:2008 10 2008 DEVELOP A REPAIR/REPLACE POLICY $11,700 $11,589 Implemented
NC0383 # 11 Y:2008 11 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,695 $1,497 Implemented
NC0383 # 12 Y:2008 12 2008 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $850 $750 Not Implemented
OR0532 # 01 Y:2008 01 2008 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $4,033 $400 Not Implemented
OR0532 # 02 Y:2008 02 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,101 $2,697 Not Implemented
OR0532 # 03 Y:2008 03 2008 INSTALL OCCUPANCY SENSORS $4,068 $13,244 Not Implemented
OR0532 # 04 Y:2008 04 2008 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $27,532 $49,504 Not Implemented
OR0532 # 05 Y:2008 05 2008 OPTIMIZE PLANT POWER FACTOR $13,750 $20,650 Not Implemented
OR0532 # 06 Y:2008 06 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $1,195 $0 Not Implemented
WV0382 # 10 Y:2008 10 2008 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $3,383 $4,160 Not Implemented