Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
212
matching recommendationsNAICS | 325 | Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0134 # 04 Y:2014 | 04 | 2014 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $4,630 | $5,700 | Not Implemented |
DL0134 # 03 Y:2014 | 03 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $16,580 | $0 | Implemented |
DL0134 # 02 Y:2014 | 02 | 2014 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $41,430 | $54,000 | Implemented |
DL0134 # 01 Y:2014 | 01 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $36,000 | $33,600 | Implemented |
DL0128 # 01 Y:2014 | 01 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $59,000 | $150,000 | Implemented |
DL0128 # 02 Y:2014 | 02 | 2014 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $28,000 | $50,000 | Not Implemented |
DL0128 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,150 | $101,600 | Implemented |
DL0128 # 05 Y:2014 | 05 | 2014 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $6,000 | $20,000 | Implemented |
DL0128 # 06 Y:2014 | 06 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $15,300 | $15,000 | Not Implemented |
DL0128 # 04 Y:2014 | 04 | 2014 | INSULATE BARE EQUIPMENT | $18,200 | $12,560 | Implemented |
DL0118 # 11 Y:2013 | 11 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,300 | $700 | Not Implemented |
DL0118 # 10 Y:2013 | 10 | 2013 | INSTALL OCCUPANCY SENSORS | $3,600 | $1,000 | Implemented |
DL0118 # 09 Y:2013 | 09 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,504 | $20,000 | Implemented |
DL0118 # 08 Y:2013 | 08 | 2013 | INSULATE BARE EQUIPMENT | $2,400 | $330 | Not Implemented |
DL0118 # 07 Y:2013 | 07 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,362 | $4,680 | Not Implemented |
DL0118 # 06 Y:2013 | 06 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $6,500 | $0 | Implemented |
DL0118 # 05 Y:2013 | 05 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $5,900 | $300 | Not Implemented |
DL0118 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,300 | $3,000 | Implemented |
DL0118 # 03 Y:2013 | 03 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,500 | $349,314 | Implemented |
DL0118 # 02 Y:2013 | 02 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,600 | $16,500 | Not Implemented |
DL0118 # 01 Y:2013 | 01 | 2013 | INSULATE BARE EQUIPMENT | $13,600 | $800 | Not Implemented |
DL0102 # 05 Y:2013 | 05 | 2013 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $4,300 | $37,600 | Not Implemented |
DL0102 # 01 Y:2013 | 01 | 2013 | REDUCE VENTILATION AIR | $31,820 | $3,200 | Implemented |
DL0102 # 02 Y:2013 | 02 | 2013 | LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION | $25,460 | $100 | Implemented |
DL0102 # 04 Y:2013 | 04 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,500 | $510 | Not Implemented |