Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,078
matching recommendationsNAICS | 32541 | Pharmaceutical and Medicine Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0397 # 07 Y:2009 | 07 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $17,728 | $0 | Implemented |
WV0397 # 08 Y:2009 | 08 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $15,726 | $1,000 | Implemented |
WV0397 # 09 Y:2009 | 09 | 2009 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,377 | $49,300 | Not Implemented |
WV0397 # 10 Y:2009 | 10 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $7,120 | $5,500 | Implemented |
WV0397 # 11 Y:2009 | 11 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,792 | $19,960 | Implemented |
SF0378 # 01 Y:2009 | 01 | 2009 | ADJUST VENTS TO MINIMIZE ENERGY USE | $4,936 | $0 | Not Implemented |
SF0378 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,697 | $0 | Implemented |
SF0378 # 03 Y:2009 | 03 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,063 | $500 | Implemented |
SF0378 # 04 Y:2009 | 04 | 2009 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $396 | $75 | Not Implemented |
SF0378 # 05 Y:2009 | 05 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $28,409 | $12,868 | Not Implemented |
SF0378 # 06 Y:2009 | 06 | 2009 | INSTALL OCCUPANCY SENSORS | $13,576 | $17,518 | Not Implemented |
SF0378 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $559 | $840 | Not Implemented |
SF0378 # 08 Y:2009 | 08 | 2009 | USE PHOTOCELL CONTROLS | $771 | $1,925 | Not Implemented |
UD0803 # 01 Y:2009 | 01 | 2009 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $393,528 | $8,000 | Implemented |
UD0803 # 02 Y:2009 | 02 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $21,371 | $3,376 | Implemented |
UD0803 # 03 Y:2009 | 03 | 2009 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $17,615 | $84,000 | Not Implemented |
UD0803 # 04 Y:2009 | 04 | 2009 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $14,916 | $25,000 | Not Implemented |
UD0803 # 05 Y:2009 | 05 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,360 | $19,600 | Not Implemented |
UD0803 # 06 Y:2009 | 06 | 2009 | REDUCE EXCESSIVE BOILER BLOWDOWN | $9,743 | $4,500 | Not Implemented |
UD0803 # 07 Y:2009 | 07 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,851 | $500 | Not Implemented |
UD0803 # 08 Y:2009 | 08 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,627 | $0 | Not Implemented |
UD0803 # 09 Y:2009 | 09 | 2009 | KEEP BOILER TUBES CLEAN | $4,480 | $1,000 | Implemented |
UD0803 # 10 Y:2009 | 10 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,845 | $4,930 | Not Implemented |
UD0803 # 11 Y:2009 | 11 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,432 | $0 | Not Implemented |
UD0803 # 12 Y:2009 | 12 | 2009 | INSTALL OCCUPANCY SENSORS | $1,959 | $1,300 | Not Implemented |