Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
35
matching recommendationsNAICS | 325412 | Pharmaceutical Preparation Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0187 # 09 Y:2017 | 09 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $1,046 | $3,200 | Not Implemented |
TT0187 # 01 Y:2017 | 01 | 2017 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $77,734 | $24,500 | Not Implemented |
TT0187 # 02 Y:2017 | 02 | 2017 | INCREASE AMOUNT OF CONDENSATE RETURNED | $52,000 | $14,250 | Implemented |
TT0187 # 03 Y:2017 | 03 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $24,005 | $30,000 | Implemented |
TT0187 # 04 Y:2017 | 04 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $19,000 | $3,000 | Implemented |
TT0187 # 05 Y:2017 | 05 | 2017 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $8,095 | $1,311 | Implemented |
TT0187 # 06 Y:2017 | 06 | 2017 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $6,126 | $2,000 | Not Implemented |
TT0187 # 07 Y:2017 | 07 | 2017 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,097 | $1,000 | Not Implemented |
TT0187 # 08 Y:2017 | 08 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,556 | $0 | Implemented |
MS0371 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,774 | $19,214 | Not Implemented |
MS0371 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,056 | $11,255 | Not Implemented |
MS0371 # 05 Y:2011 | 05 | 2011 | OPTIMIZE PLANT POWER FACTOR | $6,211 | $30,420 | Not Implemented |
MS0371 # 04 Y:2011 | 04 | 2011 | INCREASE AMOUNT OF CONDENSATE RETURNED | $7,004 | $11,785 | Not Implemented |
MS0371 # 03 Y:2011 | 03 | 2011 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,839 | $8,380 | Not Implemented |
MS0371 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,866 | $2,431 | Not Implemented |
MS0371 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $930 | $386 | Not Implemented |
MS0318 # 06 Y:2007 | 06 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $587 | $0 | Implemented |
MS0318 # 07 Y:2007 | 07 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $205 | $434 | Not Implemented |
MS0318 # 05 Y:2007 | 05 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $747 | $378 | Not Implemented |
MS0318 # 04 Y:2007 | 04 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $2,805 | $156 | Implemented |
MS0318 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,013 | $401 | Implemented |
MS0318 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,884 | $20,897 | Implemented |
MS0318 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,453 | $34,528 | Implemented |
MS0224 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $351,990 | $119,086 | n/a |
MS0224 # 01 Y:2003 | 01 | 2003 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $936,645 | $8,400,000 | n/a |