Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
399
matching recommendationsNAICS | 325510 | Paint and Coating Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0978 # 11 Y:2017 | 11 | 2017 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,391 | $3,600 | Not Implemented |
MI0312 # 05 Y:2017 | 05 | 2017 | USE PHOTOCELL CONTROLS | $9,752 | $8,000 | Implemented |
MI0312 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,284 | $33,139 | Implemented |
MI0312 # 02 Y:2017 | 02 | 2017 | OPTIMIZE PLANT POWER FACTOR | $11,092 | $31,500 | Not Implemented |
MI0312 # 03 Y:2017 | 03 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,806 | $3,600 | Implemented |
MI0312 # 04 Y:2017 | 04 | 2017 | INSTALL OCCUPANCY SENSORS | $9,922 | $1,995 | Implemented |
MI0312 # 06 Y:2017 | 06 | 2017 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,631 | $5,377 | Not Implemented |
MI0312 # 07 Y:2017 | 07 | 2017 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,544 | $19,300 | Implemented |
MI0312 # 08 Y:2017 | 08 | 2017 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,938 | $960 | Implemented |
MI0312 # 09 Y:2017 | 09 | 2017 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $4,535 | $580 | Not Implemented |
MI0312 # 10 Y:2017 | 10 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,241 | $1,660 | Implemented |
DL0170 # 04 Y:2016 | 04 | 2016 | USE SOLAR HEAT TO MAKE ELECTRICTY | $8,780 | $47,412 | Not Implemented |
DL0170 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,950 | $9,830 | Not Implemented |
DL0170 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,055 | $40,740 | Not Implemented |
DL0170 # 01 Y:2016 | 01 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $12,960 | $23,000 | Not Implemented |
OK0908 # 04 Y:2015 | 04 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,829 | $59,743 | Not Implemented |
OK0908 # 03 Y:2015 | 03 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $621 | $432 | Implemented |
OK0908 # 02 Y:2015 | 02 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,662 | $120 | Not Implemented |
OK0908 # 01 Y:2015 | 01 | 2015 | OPTIMIZE PLANT POWER FACTOR | $6,429 | $11,430 | Implemented |
UD0898 # 01 Y:2014 | 01 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $156 | $50 | Implemented |
UD0898 # 02 Y:2014 | 02 | 2014 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $11,196 | $300 | Not Implemented |
UD0898 # 03 Y:2014 | 03 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $778 | $0 | Not Implemented |
UD0898 # 04 Y:2014 | 04 | 2014 | COVER OPEN TANKS | $57 | $200 | Implemented |
UD0898 # 05 Y:2014 | 05 | 2014 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $8,127 | $6,567 | Not Implemented |
UD0898 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,748 | $2,320 | Not Implemented |