Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsNAICS | 32562 | Toilet Preparation Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0370 # 10 Y:2005 | 10 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $313 | $760 | Not Implemented |
UF0370 # 09 Y:2005 | 09 | 2005 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $47,299 | $130,000 | Implemented |
UF0370 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $926 | $959 | Not Implemented |
UF0370 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $4,053 | $1,317 | Implemented |
UF0370 # 06 Y:2005 | 06 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,525 | $0 | Not Implemented |
UF0370 # 05 Y:2005 | 05 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $43,146 | $1,190 | Not Implemented |
UF0370 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,994 | $731 | Not Implemented |
UF0370 # 03 Y:2005 | 03 | 2005 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $20,435 | $56,000 | Implemented |
UF0370 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,004 | $1,286 | Not Implemented |
UF0370 # 01 Y:2005 | 01 | 2005 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $2,736 | $1,212 | Implemented |
UF0370 # 11 Y:2005 | 11 | 2005 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,313 | $0 | Implemented |
UF0370 # 12 Y:2005 | 12 | 2005 | IMPROVE SPACE COMFORT CONDITIONING | $3,223 | $12,400 | Not Implemented |
GT0793 # 02 Y:2004 | 02 | 2004 | USE SYNTHETIC LUBRICANT | $2,500 | $0 | Not Implemented |
GT0793 # 08 Y:2004 | 08 | 2004 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $11,000 | $9,090 | Not Implemented |
GT0793 # 07 Y:2004 | 07 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,890 | $8,000 | Not Implemented |
GT0793 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $480 | $1,850 | Not Implemented |
GT0793 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,280 | $2 | Not Implemented |
GT0793 # 04 Y:2004 | 04 | 2004 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $270 | $758 | Not Implemented |
GT0793 # 03 Y:2004 | 03 | 2004 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $2,040 | $0 | Not Implemented |
GT0793 # 01 Y:2004 | 01 | 2004 | COMBINE UTILITY METERS | $5,142 | $8,000 | Not Implemented |
SD0343 # 06 Y:2004 | 06 | 2004 | INCREASE USE OF AUTOMATION | $75,100 | $65,000 | Not Implemented |
SD0343 # 05 Y:2004 | 05 | 2004 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $10,692 | $18,500 | Not Implemented |
SD0343 # 04 Y:2004 | 04 | 2004 | USE EVAPORATION TO CONCENTRATE MATERIAL | $11,520 | $12,000 | Not Implemented |
SD0343 # 03 Y:2004 | 03 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $2,381 | $2,113 | Not Implemented |
SD0343 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,576 | $440 | Not Implemented |