Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,415
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0727 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,140 | $26,760 | n/a |
CO0727 # 04 Y:2016 | 04 | 2016 | INSTALL OCCUPANCY SENSORS | $2,660 | $2,570 | n/a |
CO0727 # 05 Y:2016 | 05 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $550 | $2,280 | n/a |
CO0727 # 06 Y:2016 | 06 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $250 | $280 | n/a |
WV0530 # 01 Y:2016 | 01 | 2016 | INSULATE BARE EQUIPMENT | $45,649 | $8,838 | Implemented |
WV0530 # 02 Y:2016 | 02 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $44,558 | $72,000 | Implemented |
WV0530 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,714 | $16,453 | Implemented |
WV0530 # 04 Y:2016 | 04 | 2016 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $15,987 | $1,000 | Implemented |
WV0530 # 05 Y:2016 | 05 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $8,519 | $1,125 | Not Implemented |
WV0530 # 06 Y:2016 | 06 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,493 | $128 | Not Implemented |
WV0530 # 07 Y:2016 | 07 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $6,845 | $5,000 | Implemented |
WV0530 # 08 Y:2016 | 08 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,395 | $27,920 | Not Implemented |
WV0530 # 09 Y:2016 | 09 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,409 | $1,036 | Implemented |
WV0530 # 10 Y:2016 | 10 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,195 | $8,450 | Implemented |
MA0759 # 01 Y:2016 | 01 | 2016 | REDUCE VENTILATION AIR | $11,226 | $14,820 | Not Implemented |
MA0759 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,476 | $6,333 | Implemented |
MA0759 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,502 | $3,367 | Implemented |
MA0759 # 04 Y:2016 | 04 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $825 | $6,402 | Implemented |
OK0947 # 06 Y:2016 | 06 | 2016 | INSTALL SET-BACK TIMERS | $483 | $410 | Not Implemented |
OK0947 # 07 Y:2016 | 07 | 2016 | OPTIMIZE PLANT POWER FACTOR | $4,680 | $27,500 | Not Implemented |
OK0947 # 08 Y:2016 | 08 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $368 | $822 | Not Implemented |
OK0947 # 09 Y:2016 | 09 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,092 | $2,000 | Not Implemented |
OK0947 # 10 Y:2016 | 10 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $362 | $540 | Not Implemented |
OK0947 # 01 Y:2016 | 01 | 2016 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $11,871 | $92,000 | Not Implemented |
OK0947 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $985 | $3,780 | Not Implemented |