Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
421
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0284 # 03 Y:2005 | 03 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,583 | $18,820 | Implemented |
BD0284 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,801 | $1,464 | Implemented |
BD0284 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $170 | $360 | Implemented |
BD0284 # 06 Y:2005 | 06 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $7,427 | $4,800 | Implemented |
BD0284 # 07 Y:2005 | 07 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $911 | $0 | Not Implemented |
BD0284 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $967 | $900 | Implemented |
BD0284 # 09 Y:2005 | 09 | 2005 | MINIMIZE WATER USAGE | $3,546 | $2,240 | Implemented |
IC0099 # 01 Y:2005 | 01 | 2005 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $6,719 | $35,000 | Not Implemented |
IC0099 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,085 | $66,591 | Not Implemented |
IC0099 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $246 | $0 | Implemented |
IC0099 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,577 | $1,200 | Implemented |
IC0099 # 05 Y:2005 | 05 | 2005 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $6,852 | $1,520 | Implemented |
IC0099 # 06 Y:2005 | 06 | 2005 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $671 | $48 | Not Implemented |
IC0099 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $92 | $364 | Not Implemented |
IC0099 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $531 | $1,121 | Not Implemented |
BD0268 # 01 Y:2004 | 01 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $352,557 | $1,500,000 | Implemented |
BD0268 # 02 Y:2004 | 02 | 2004 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $81,415 | $130,000 | Implemented |
BD0268 # 03 Y:2004 | 03 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $40,434 | $49,000 | Implemented |
BD0268 # 04 Y:2004 | 04 | 2004 | HEAT WATER WITH EXHAUST HEAT | $31,790 | $35,000 | Implemented |
BD0268 # 05 Y:2004 | 05 | 2004 | ADD AREA LIGHTING SWITCHES | $14,266 | $9,000 | Not Implemented |
BD0268 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,170 | $200 | Implemented |
BD0268 # 07 Y:2004 | 07 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,701 | $1,500 | Implemented |
BD0268 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $784 | $1,320 | Not Implemented |
BD0268 # 09 Y:2004 | 09 | 2004 | USE PHOTOCELL CONTROLS | $605 | $240 | Not Implemented |
BD0268 # 10 Y:2004 | 10 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $461 | $20 | Implemented |