Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
452
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0377 # 08 Y:2006 | 08 | 2006 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $626,232 | $1,134,871 | Not Implemented |
UF0377 # 09 Y:2006 | 09 | 2006 | IMPROVE PROCESS CONTROL TO PREVENT SPILLS OF MATERIAL | $4,718 | $463 | Not Implemented |
UF0377 # 10 Y:2006 | 10 | 2006 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $3,000 | $0 | Not Implemented |
MI0127 # 01 Y:2006 | 01 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $34,584 | $3,984 | Not Implemented |
MI0127 # 02 Y:2006 | 02 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $25,742 | $46,506 | Not Implemented |
MI0127 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,532 | $33,405 | Implemented |
MI0127 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,597 | $1,074 | Implemented |
MI0127 # 05 Y:2006 | 05 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,247 | $30 | Not Implemented |
MI0127 # 06 Y:2006 | 06 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $9,084 | $4,800 | Implemented |
MI0127 # 07 Y:2006 | 07 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,640 | $0 | Not Implemented |
MI0127 # 08 Y:2006 | 08 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,107 | $3,878 | Implemented |
MI0121 # 01 Y:2006 | 01 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,669 | $0 | Implemented |
MI0121 # 02 Y:2006 | 02 | 2006 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $3,836 | $122 | Not Implemented |
MI0121 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $2,209 | $420 | Implemented |
MI0121 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,015 | $964 | Implemented |
MI0121 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $996 | $56 | Not Implemented |
MI0121 # 06 Y:2006 | 06 | 2006 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $362 | $0 | Not Implemented |
MI0109 # 01 Y:2005 | 01 | 2005 | INSTALL EQUIPMENT TO MOVE PRODUCT | $30,000 | $20,000 | Not Implemented |
MI0109 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,226 | $1,350 | Not Implemented |
MI0109 # 03 Y:2005 | 03 | 2005 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $7,803 | $560 | Not Implemented |
MI0109 # 04 Y:2005 | 04 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,952 | $400 | Not Implemented |
MI0109 # 05 Y:2005 | 05 | 2005 | INSULATE BARE EQUIPMENT | $4,352 | $1,010 | Not Implemented |
MI0109 # 06 Y:2005 | 06 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $3,825 | $346 | Not Implemented |
MI0109 # 07 Y:2005 | 07 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $828 | $0 | Not Implemented |
MI0109 # 08 Y:2005 | 08 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $685 | $156 | Not Implemented |