Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
558
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0081 # 06 Y:2004 | 06 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,255 | $190 | Not Implemented |
TA0081 # 07 Y:2004 | 07 | 2004 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,035 | $0 | Implemented |
TA0081 # 08 Y:2004 | 08 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,880 | $0 | Not Implemented |
TA0065 # 01 Y:2003 | 01 | 2003 | REDESIGN PROCESS | $75,086 | $0 | Implemented |
TA0065 # 02 Y:2003 | 02 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $64,800 | $5,200 | Implemented |
TA0065 # 03 Y:2003 | 03 | 2003 | USE "WASH-LESS" PROCESSING EQUIPMENT | $49,000 | $1,768 | Not Implemented |
TA0065 # 04 Y:2003 | 04 | 2003 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $37,440 | $1,027 | Not Implemented |
TA0065 # 05 Y:2003 | 05 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,900 | $0 | Implemented |
TA0065 # 06 Y:2003 | 06 | 2003 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $2,426 | $6,000 | Implemented |
TA0065 # 07 Y:2003 | 07 | 2003 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,793 | $0 | Implemented |
TA0065 # 08 Y:2003 | 08 | 2003 | MOVE BOILER TO MORE EFFICIENT LOCATION | $1,422 | $1,894 | Implemented |
TA0065 # 09 Y:2003 | 09 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $306 | $140 | Implemented |
TA0065 # 10 Y:2003 | 10 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $194 | $0 | Not Implemented |
TA0065 # 11 Y:2003 | 11 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $146 | $142 | Not Implemented |
TA0060 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,300 | $11,530 | Not Implemented |
TA0060 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,880 | $150 | Not Implemented |
TA0060 # 03 Y:2003 | 03 | 2003 | PAY UTILITY BILLS ON TIME | $4,647 | $0 | Not Implemented |
TA0060 # 04 Y:2003 | 04 | 2003 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $4,700 | $0 | Not Implemented |
TA0060 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $2,140 | $506 | Not Implemented |
TA0060 # 06 Y:2003 | 06 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $670 | $1,060 | Not Implemented |
TA0060 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $460 | $83 | Not Implemented |
AM0438 # 01 Y:2003 | 01 | 2003 | OPTIMIZE PLANT POWER FACTOR | $12,900 | $18,200 | Implemented |
AM0438 # 02 Y:2003 | 02 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,900 | $0 | Implemented |
AM0438 # 03 Y:2003 | 03 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,700 | $0 | Implemented |
AM0438 # 04 Y:2003 | 04 | 2003 | RECOVER AND REUSE WASTE MATERIAL | $2,350 | $0 | Implemented |