Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
134
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0756 # 05 Y:2008 | 05 | 2008 | INSULATE BARE EQUIPMENT | $36,391 | $6,600 | Not Implemented |
OK0756 # 06 Y:2008 | 06 | 2008 | INSULATE BARE EQUIPMENT | $12,665 | $8,800 | Not Implemented |
MS0321 # 01 Y:2007 | 01 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,161 | $1,400 | Not Implemented |
MS0321 # 02 Y:2007 | 02 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,742 | $306 | Implemented |
MS0321 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,455 | $2,724 | Not Implemented |
MS0321 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $854 | $455 | Not Implemented |
OK0752 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,323 | $2,319 | Not Implemented |
OK0752 # 02 Y:2007 | 02 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,360 | $0 | Not Implemented |
OK0752 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,978 | $1,000 | Not Implemented |
OK0752 # 04 Y:2007 | 04 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $3,226 | $5,328 | Not Implemented |
OK0752 # 05 Y:2007 | 05 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $9,113 | $12,000 | Not Implemented |
OK0752 # 06 Y:2007 | 06 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $239 | $70 | Not Implemented |
OK0752 # 07 Y:2007 | 07 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,114 | $7,711 | Not Implemented |
OK0752 # 08 Y:2007 | 08 | 2007 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,548 | $0 | Not Implemented |
OK0752 # 09 Y:2007 | 09 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $20,273 | $2,500 | Not Implemented |
OK0752 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $499 | $8,116 | Not Implemented |
LL0267 # 01 Y:2007 | 01 | 2007 | INSULATE BARE EQUIPMENT | $23,653 | $3,315 | Implemented |
LL0267 # 02 Y:2007 | 02 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,665 | $30 | Not Implemented |
LL0267 # 03 Y:2007 | 03 | 2007 | USE PHOTOCELL CONTROLS | $3,379 | $360 | Not Implemented |
LL0267 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,794 | $1,280 | Implemented |
LL0267 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $553 | $180 | Not Implemented |
LL0267 # 06 Y:2007 | 06 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $155 | $319 | Not Implemented |
LL0267 # 07 Y:2007 | 07 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $142 | $303 | Not Implemented |
LL0267 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $180 | $140 | Not Implemented |
LL0267 # 09 Y:2007 | 09 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,060 | $2,034 | Not Implemented |