Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
241
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0777 # 01 Y:2009 | 01 | 2009 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $164,328 | $490,000 | Implemented |
OK0777 # 02 Y:2009 | 02 | 2009 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $26,234 | $0 | Implemented |
OK0777 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,889 | $19,448 | Not Implemented |
OK0777 # 04 Y:2009 | 04 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,136 | $3,129 | Implemented |
OK0777 # 05 Y:2009 | 05 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $28,753 | $33,300 | Implemented |
OK0777 # 06 Y:2009 | 06 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $2,638 | $779 | Implemented |
OK0764 # 01 Y:2008 | 01 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,109 | $5,086 | Not Implemented |
OK0764 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,596 | $14,878 | Not Implemented |
OK0764 # 03 Y:2008 | 03 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $477 | $1,165 | Not Implemented |
OK0764 # 04 Y:2008 | 04 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $22,038 | $14,300 | Not Implemented |
OK0764 # 05 Y:2008 | 05 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $7,000 | $0 | Not Implemented |
OK0764 # 06 Y:2008 | 06 | 2008 | CLOSE OFF UNNEEDED STEAM LINES | $7,161 | $0 | Not Implemented |
OK0764 # 07 Y:2008 | 07 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $28,620 | $23,375 | Not Implemented |
OK0764 # 08 Y:2008 | 08 | 2008 | REDUCE EXCESSIVE BOILER BLOWDOWN | $2,877 | $0 | Not Implemented |
OK0745 # 01 Y:2007 | 01 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,891 | $360 | Implemented |
OK0745 # 02 Y:2007 | 02 | 2007 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $57,727 | $3,600 | Not Implemented |
OK0745 # 03 Y:2007 | 03 | 2007 | INSULATE BARE EQUIPMENT | $13,884 | $4,859 | Implemented |
OK0745 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $2,384 | $744 | Not Implemented |
OK0745 # 05 Y:2007 | 05 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,437 | $1,574 | Not Implemented |
OK0745 # 06 Y:2007 | 06 | 2007 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $11,998 | $9,010 | Not Implemented |
OK0745 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,171 | $81,808 | Not Implemented |
OK0745 # 08 Y:2007 | 08 | 2007 | OPTIMIZE PLANT POWER FACTOR | $1,509 | $6,760 | Not Implemented |
OK0745 # 09 Y:2007 | 09 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,516 | $7,600 | Not Implemented |
OK0745 # 10 Y:2007 | 10 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $609 | $3,125 | Not Implemented |
OK0745 # 11 Y:2007 | 11 | 2007 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $37,616 | $286,361 | Implemented |