Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,122
matching recommendationsNAICS | 32611 | Plastics Packaging Materials and Unlaminated Film and Sheet Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0611 # 03 Y:2018 | 03 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,064 | $100 | Not Implemented |
NC0611 # 04 Y:2018 | 04 | 2018 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $7,227 | $35,000 | Not Implemented |
NC0611 # 05 Y:2018 | 05 | 2018 | DEVELOP A REPAIR/REPLACE POLICY | $2,887 | $5,685 | Implemented |
NC0611 # 06 Y:2018 | 06 | 2018 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,662 | $200 | Implemented |
LE0453 # 01 Y:2018 | 01 | 2018 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $70,484 | $4,500 | Implemented |
LE0453 # 02 Y:2018 | 02 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,972 | $1,125 | Not Implemented |
LE0453 # 03 Y:2018 | 03 | 2018 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,248 | $4,000 | Not Implemented |
LE0453 # 04 Y:2018 | 04 | 2018 | INSTALL OCCUPANCY SENSORS | $1,037 | $1,550 | Not Implemented |
LE0453 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,499 | $3,938 | Implemented |
LE0453 # 06 Y:2018 | 06 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,507 | $11,250 | Implemented |
LE0453 # 07 Y:2018 | 07 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,514 | $19,688 | Implemented |
LE0453 # 08 Y:2018 | 08 | 2018 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $27,940 | $105,000 | Not Implemented |
UD0975 # 01 Y:2017 | 01 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $14,600 | $0 | Implemented |
UD0975 # 02 Y:2017 | 02 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,179 | $0 | Implemented |
UD0975 # 03 Y:2017 | 03 | 2017 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $17,029 | $68 | Implemented |
UD0975 # 04 Y:2017 | 04 | 2017 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $9,406 | $500 | Not Implemented |
UD0975 # 05 Y:2017 | 05 | 2017 | COVER OPEN TANKS | $29,884 | $2,350 | Not Implemented |
UD0975 # 06 Y:2017 | 06 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $16,737 | $2,000 | Not Implemented |
UD0975 # 07 Y:2017 | 07 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,640 | $1,600 | Implemented |
UD0975 # 08 Y:2017 | 08 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,964 | $2,000 | Not Implemented |
UD0975 # 09 Y:2017 | 09 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $1,684 | $1,500 | Implemented |
UD0975 # 10 Y:2017 | 10 | 2017 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $4,642 | $5,000 | Not Implemented |
UD0975 # 11 Y:2017 | 11 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $45,148 | $47,000 | Implemented |
UD0975 # 12 Y:2017 | 12 | 2017 | INSTALL OCCUPANCY SENSORS | $3,441 | $1,931 | Implemented |
UD0961 # 01 Y:2017 | 01 | 2017 | USE RADIANT HEATER FOR SPOT HEATING | $23,931 | $14,250 | Not Implemented |