Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,122
matching recommendationsNAICS | 32611 | Plastics Packaging Materials and Unlaminated Film and Sheet Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0449 # 01 Y:2014 | 01 | 2014 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $64,237 | $1,500,000 | Implemented |
BD0449 # 02 Y:2014 | 02 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $13,551 | $16,500 | Not Implemented |
BD0449 # 03 Y:2014 | 03 | 2014 | USE PHOTOCELL CONTROLS | $12,784 | $7,575 | Implemented |
BD0449 # 04 Y:2014 | 04 | 2014 | DISCONNECT BALLASTS | $9,963 | $725 | Not Implemented |
BD0449 # 05 Y:2014 | 05 | 2014 | INSTALL OCCUPANCY SENSORS | $3,233 | $750 | Not Implemented |
BD0449 # 06 Y:2014 | 06 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,491 | $20 | Implemented |
BD0449 # 07 Y:2014 | 07 | 2014 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,288 | $40 | Not Implemented |
BD0449 # 08 Y:2014 | 08 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,827 | $2,800 | Implemented |
BD0449 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $739 | $600 | Not Implemented |
BD0449 # 10 Y:2014 | 10 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $407 | $700 | Not Implemented |
MZ0147 # 01 Y:2014 | 01 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $871 | $360 | Implemented |
MZ0147 # 02 Y:2014 | 02 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $63 | $235 | Implemented |
MZ0147 # 03 Y:2014 | 03 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $63 | $235 | Implemented |
MZ0147 # 04 Y:2014 | 04 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $423 | $470 | Implemented |
MZ0147 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,562 | $42,645 | Implemented |
MZ0147 # 06 Y:2014 | 06 | 2014 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,184 | $600 | Implemented |
MZ0147 # 07 Y:2014 | 07 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,950 | $5,290 | Not Implemented |
MZ0147 # 08 Y:2014 | 08 | 2014 | INSULATE BARE EQUIPMENT | $2,616 | $2,613 | Not Implemented |
MZ0147 # 09 Y:2014 | 09 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,212 | $420 | Implemented |
MZ0147 # 10 Y:2014 | 10 | 2014 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $3,158 | $250 | Implemented |
WV0482 # 01 Y:2014 | 01 | 2014 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $177,357 | $198,000 | Not Implemented |
WV0482 # 02 Y:2014 | 02 | 2014 | REPAIR OR REPLACE STEAM TRAPS | $135,791 | $7,100 | Implemented |
WV0482 # 03 Y:2014 | 03 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $37,833 | $0 | Not Implemented |
WV0482 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,141 | $51,865 | Implemented |
WV0482 # 05 Y:2014 | 05 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $35,144 | $1,000 | Implemented |