IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

80

matching recommendations
Reset
NAICS 32612 Plastics Pipe, Pipe Fitting, and Unlaminated Profile Shape Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DL0144 # 12 Y:2015 12 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $39,910 $50,580 Not Implemented
DL0144 # 11 Y:2015 11 2015 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $12,280 $44,260 Not Implemented
DL0144 # 10 Y:2015 10 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $14,820 $5,950 Implemented
DL0144 # 09 Y:2015 09 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $12,505 $14,190 Implemented
DL0144 # 08 Y:2015 08 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $25,011 $29,090 Implemented
DL0144 # 07 Y:2015 07 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $47,229 $126,010 Not Implemented
DL0144 # 06 Y:2015 06 2015 TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS $4,116 $33,900 Not Implemented
DL0144 # 05 Y:2015 05 2015 REDUCE VENTILATION AIR $17,474 $12,465 Not Implemented
DL0144 # 04 Y:2015 04 2015 TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS $24,707 $43,805 Not Implemented
DL0144 # 03 Y:2015 03 2015 REDUCE VENTILATION AIR $71,556 $20,425 Not Implemented
DL0144 # 18 Y:2015 18 2015 REDUCE VENTILATION AIR $8,800 $7,920 Not Implemented
DL0144 # 01 Y:2015 01 2015 INCREASE AMOUNT OF CONDENSATE RETURNED $112,390 $100,000 Implemented
DL0144 # 19 Y:2015 19 2015 INSTALL OCCUPANCY SENSORS $7,230 $9,840 Not Implemented
DL0144 # 17 Y:2015 17 2015 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $31,880 $35,865 Not Implemented
LE0169 # 06 Y:2003 06 2003 INSTALL OCCUPANCY SENSORS $1,034 $675 Not Implemented
LE0169 # 05 Y:2003 05 2003 INSULATE BARE EQUIPMENT $862 $119 Implemented
LE0169 # 04 Y:2003 04 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,067 $0 Implemented
LE0169 # 01 Y:2003 01 2003 INSTALL TIMERS AND/OR THERMOSTATS $1,674 $1,050 Implemented
LE0169 # 02 Y:2003 02 2003 INSTALL TIMERS AND/OR THERMOSTATS $2,194 $1,250 Implemented
LE0169 # 03 Y:2003 03 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,635 $1,000 Not Implemented
LE0168 # 01 Y:2003 01 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,831 $1,000 Not Implemented
LE0168 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,030 $2,638 Implemented
LE0168 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,082 $100 Implemented
LE0168 # 03 Y:2003 03 2003 INSTALL TIMERS AND/OR THERMOSTATS $1,053 $1,000 Not Implemented
LE0168 # 02 Y:2003 02 2003 INSTALL TIMERS AND/OR THERMOSTATS $5,145 $1,050 Not Implemented