Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
98
matching recommendationsNAICS | 326121 | Unlaminated Plastics Profile Shape Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD1005 # 03 Y:2019 | 03 | 2019 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,736 | $12,025 | Not Implemented |
UD1005 # 04 Y:2019 | 04 | 2019 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,555 | $0 | Not Implemented |
UD1005 # 01 Y:2019 | 01 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,162 | $50 | Not Implemented |
UD1005 # 02 Y:2019 | 02 | 2019 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,649 | $700 | Not Implemented |
WV0488 # 05 Y:2014 | 05 | 2014 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,558 | $4,320 | Not Implemented |
WV0488 # 12 Y:2014 | 12 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $134 | $150 | Not Implemented |
WV0488 # 07 Y:2014 | 07 | 2014 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,003 | $1,000 | Implemented |
WV0488 # 09 Y:2014 | 09 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $571 | $120 | Implemented |
WV0488 # 10 Y:2014 | 10 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $444 | $320 | Implemented |
WV0488 # 11 Y:2014 | 11 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $327 | $221 | Implemented |
WV0488 # 08 Y:2014 | 08 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $901 | $16 | Not Implemented |
WV0488 # 03 Y:2014 | 03 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,735 | $214 | Implemented |
WV0488 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,681 | $1,893 | Implemented |
WV0488 # 02 Y:2014 | 02 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $2,722 | $6,898 | Not Implemented |
WV0488 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,665 | $9,243 | Implemented |
WV0488 # 06 Y:2014 | 06 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,203 | $1,160 | Not Implemented |
UD0895 # 10 Y:2014 | 10 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,520 | $4,275 | Implemented |
UD0895 # 06 Y:2014 | 06 | 2014 | INSTALL OCCUPANCY SENSORS | $1,252 | $2,900 | Not Implemented |
UD0895 # 04 Y:2014 | 04 | 2014 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,209 | $0 | Implemented |
UD0895 # 08 Y:2014 | 08 | 2014 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,823 | $16,000 | Implemented |
UD0895 # 09 Y:2014 | 09 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,388 | $800 | Implemented |
UD0895 # 05 Y:2014 | 05 | 2014 | ADD AREA LIGHTING SWITCHES | $1,613 | $1,575 | Implemented |
UD0895 # 07 Y:2014 | 07 | 2014 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $249 | $510 | Implemented |
UD0895 # 01 Y:2014 | 01 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $72,083 | $0 | Implemented |
UD0895 # 02 Y:2014 | 02 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $21,208 | $0 | Implemented |