Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
479
matching recommendationsNAICS | 32616 | Plastics Bottle Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0938 # 10 Y:2016 | 10 | 2016 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $372,611 | $70,000 | Not Implemented |
OK0938 # 11 Y:2016 | 11 | 2016 | OPTIMIZE PLANT POWER FACTOR | $26,300 | $47,542 | Implemented |
OK0938 # 12 Y:2016 | 12 | 2016 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $308,836 | $1,371,615 | Not Implemented |
WM0083 # 01 Y:2016 | 01 | 2016 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $61,468 | $22,995 | Not Implemented |
WM0083 # 02 Y:2016 | 02 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $34,888 | $8,785 | Not Implemented |
WM0083 # 03 Y:2016 | 03 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $27,491 | $7,200 | Implemented |
WM0083 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,901 | $15,200 | Implemented |
WM0083 # 05 Y:2016 | 05 | 2016 | INSULATE BARE EQUIPMENT | $12,261 | $1,680 | Not Implemented |
WM0083 # 06 Y:2016 | 06 | 2016 | INSTALL OCCUPANCY SENSORS | $1,673 | $1,425 | Implemented |
WM0083 # 07 Y:2016 | 07 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,105 | $2,490 | Implemented |
WM0083 # 08 Y:2016 | 08 | 2016 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $273 | $695 | Not Implemented |
CO0720 # 01 Y:2016 | 01 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $14,640 | $62,670 | Not Implemented |
CO0720 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,840 | $300 | Implemented |
CO0720 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,190 | $67,155 | Implemented |
CO0720 # 04 Y:2016 | 04 | 2016 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $5,510 | $27,600 | Not Implemented |
CO0720 # 05 Y:2016 | 05 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $930 | $1,330 | Not Implemented |
SU0407 # 01 Y:2016 | 01 | 2016 | DISCONNECT BALLASTS | $76 | $0 | Not Implemented |
SU0407 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $22,191 | $1,340 | Not Implemented |
SU0407 # 03 Y:2016 | 03 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,289 | $737 | Not Implemented |
SU0407 # 04 Y:2016 | 04 | 2016 | REDUCE VENTILATION AIR | $5,800 | $523 | Not Implemented |
SU0407 # 05 Y:2016 | 05 | 2016 | ELIMINATE/REDUCE AN OPERATION | $2,255 | $1,215 | Not Implemented |
SU0407 # 06 Y:2016 | 06 | 2016 | INSTALL / REPAIR INSULATION ON STEAM LINES | $231 | $370 | Not Implemented |
SU0407 # 07 Y:2016 | 07 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $219 | $312 | Not Implemented |
SU0407 # 08 Y:2016 | 08 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $181 | $259 | Not Implemented |
SU0407 # 09 Y:2016 | 09 | 2016 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $262 | $591 | Not Implemented |