Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

122

matching recommendations
Reset
NAICS 32619 Other Plastics Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0296 # 06 Y:2010 06 2010 INSTALL OCCUPANCY SENSORS $455 $420 Not Implemented
LE0296 # 07 Y:2010 07 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $418 $182 Implemented
LE0296 # 08 Y:2010 08 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,738 $17,123 Not Implemented
LE0287 # 01 Y:2009 01 2009 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $184,606 $250,000 Not Implemented
LE0287 # 02 Y:2009 02 2009 INSTALL TIMERS AND/OR THERMOSTATS $220,823 $50,000 Not Implemented
LE0287 # 03 Y:2009 03 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $79,515 $8,000 Not Implemented
LE0287 # 04 Y:2009 04 2009 INSTALL TIMERS AND/OR THERMOSTATS $36,003 $650 Not Implemented
LE0287 # 05 Y:2009 05 2009 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $19,644 $17,000 Not Implemented
LE0287 # 06 Y:2009 06 2009 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $13,621 $7,167 Not Implemented
LE0287 # 07 Y:2009 07 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,058 $1,840 Implemented
LE0287 # 08 Y:2009 08 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,998 $27,281 Not Implemented
LE0222 # 01 Y:2005 01 2005 ADD ADDITIONAL PRODUCTION SHIFT $96,000 $5,000 Not Implemented
LE0222 # 02 Y:2005 02 2005 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $13,410 $49,000 Not Implemented
LE0222 # 03 Y:2005 03 2005 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $5,760 $5,100 Not Implemented
LE0222 # 04 Y:2005 04 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,048 $2,000 Not Implemented
LE0222 # 05 Y:2005 05 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $2,793 $815 Not Implemented
LE0222 # 06 Y:2005 06 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,752 $200 Not Implemented
LE0222 # 07 Y:2005 07 2005 RECOVER WASTE HEAT FROM EQUIPMENT $1,714 $7,800 Not Implemented
LE0222 # 08 Y:2005 08 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $513 $480 Not Implemented
LE0222 # 09 Y:2005 09 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,823 $500 Not Implemented
LE0224 # 01 Y:2005 01 2005 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $95,556 $262,000 Not Implemented
LE0224 # 02 Y:2005 02 2005 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $35,540 $80,000 Not Implemented
LE0224 # 03 Y:2005 03 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $49,379 $10,700 Not Implemented
LE0224 # 04 Y:2005 04 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $28,953 $4,000 Not Implemented
LE0224 # 05 Y:2005 05 2005 INSULATE BARE EQUIPMENT $20,478 $22,000 Not Implemented