Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,797
matching recommendationsNAICS | 326199 | All Other Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0410 # 07 Y:2008 | 07 | 2008 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $22,978 | $11,522 | Not Implemented |
SD0410 # 08 Y:2008 | 08 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,624 | $24,471 | Not Implemented |
SD0410 # 09 Y:2008 | 09 | 2008 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $10,867 | $500 | Not Implemented |
SD0410 # 10 Y:2008 | 10 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,041 | $5,849 | Not Implemented |
SD0410 # 11 Y:2008 | 11 | 2008 | INSTALL SKYLIGHTS | $7,467 | $22,980 | Implemented |
SD0410 # 12 Y:2008 | 12 | 2008 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,185 | $0 | Not Implemented |
IC0144 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,363 | $12,122 | Not Implemented |
IC0144 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,224 | $5,101 | Implemented |
IC0144 # 03 Y:2008 | 03 | 2008 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $461 | $0 | Implemented |
IC0144 # 04 Y:2008 | 04 | 2008 | INSTALL OCCUPANCY SENSORS | $533 | $781 | Implemented |
IC0144 # 05 Y:2008 | 05 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $68 | $0 | Implemented |
IC0144 # 06 Y:2008 | 06 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,031 | $4,364 | Implemented |
IC0144 # 07 Y:2008 | 07 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,002 | $2,000 | Implemented |
IC0144 # 08 Y:2008 | 08 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $431 | $0 | Not Implemented |
IC0144 # 09 Y:2008 | 09 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $222 | $0 | Implemented |
IC0144 # 10 Y:2008 | 10 | 2008 | USE SOLAR HEAT TO HEAT WATER | $305 | $1,965 | Not Implemented |
IC0144 # 11 Y:2008 | 11 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $307 | $0 | Not Implemented |
IC0144 # 12 Y:2008 | 12 | 2008 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $48 | $0 | Implemented |
IC0144 # 13 Y:2008 | 13 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $633 | $920 | Implemented |
IC0143 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,805 | $14,430 | Not Implemented |
IC0143 # 02 Y:2008 | 02 | 2008 | DISCONNECT BALLASTS | $26 | $26 | Implemented |
IC0143 # 03 Y:2008 | 03 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $338 | $0 | Implemented |
IC0143 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $944 | $162 | Implemented |
IC0143 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $90 | $142 | Implemented |
IC0143 # 06 Y:2008 | 06 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,385 | $1,541 | Implemented |