Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

63

matching recommendations
Reset
NAICS 3262 Rubber Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0621 # 02 Y:2018 02 2018 INSTALL OCCUPANCY SENSORS $134 $150 Not Implemented
NC0621 # 03 Y:2018 03 2018 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,222 $390 Not Implemented
NC0621 # 04 Y:2018 04 2018 INSTALL / REPAIR INSULATION ON STEAM LINES $6,697 $5,350 Not Implemented
NC0621 # 05 Y:2018 05 2018 INCREASE AMOUNT OF CONDENSATE RETURNED $943 $1,000 Not Implemented
NC0621 # 06 Y:2018 06 2018 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $16,097 $500 Not Implemented
NC0621 # 01 Y:2018 01 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $22,870 $54,127 Not Implemented
UD0988 # 09 Y:2018 09 2018 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $3,857 $6,000 Not Implemented
UD0988 # 08 Y:2018 08 2018 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $5,857 $11,500 Not Implemented
UD0988 # 05 Y:2018 05 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,805 $2,571 Not Implemented
UD0988 # 03 Y:2018 03 2018 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $7,256 $3,172 Not Implemented
UD0988 # 04 Y:2018 04 2018 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $291 $0 Not Implemented
UD0988 # 02 Y:2018 02 2018 USE OPTIMUM THICKNESS INSULATION $2,434 $2,072 Not Implemented
UD0988 # 07 Y:2018 07 2018 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE $22,500 $20,000 Not Implemented
UD0988 # 01 Y:2018 01 2018 TURN OFF EQUIPMENT WHEN NOT IN USE $6,505 $0 Not Implemented
UD0988 # 06 Y:2018 06 2018 INSTALL OCCUPANCY SENSORS $1,216 $595 Not Implemented
IP0105 # 06 Y:2018 06 2018 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,424 $7,315 Implemented
IP0105 # 02 Y:2018 02 2018 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $670 $0 Not Implemented
IP0105 # 04 Y:2018 04 2018 INSTALL OCCUPANCY SENSORS $863 $474 Implemented
IP0105 # 05 Y:2018 05 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $36,239 $98,464 Implemented
IP0105 # 03 Y:2018 03 2018 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,081 $702 Implemented
IP0105 # 01 Y:2018 01 2018 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,219 $0 Implemented
IP0104 # 04 Y:2018 04 2018 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $22,395 $5,924 Implemented
IP0104 # 05 Y:2018 05 2018 INSTALL OCCUPANCY SENSORS $1,594 $475 Implemented
IP0104 # 07 Y:2018 07 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,529 $4,887 Implemented
IP0104 # 06 Y:2018 06 2018 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,678 $2,725 Implemented