IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

228

matching recommendations
Reset
NAICS 32711 Pottery, Ceramics, and Plumbing Fixture Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0313 # 08 Y:2005 08 2005 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,051 $3,441 Not Implemented
SF0313 # 09 Y:2005 09 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,672 $8,006 Not Implemented
SF0313 # 10 Y:2005 10 2005 USE PHOTOCELL CONTROLS $3,196 $7,650 Not Implemented
SF0313 # 11 Y:2005 11 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,515 $13,681 Not Implemented
BD0269 # 01 Y:2004 01 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,588 $225 Implemented
BD0269 # 02 Y:2004 02 2004 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $3,568 $3,200 Implemented
BD0269 # 03 Y:2004 03 2004 DIRECT WARMEST AIR TO COMBUSTION INTAKE $2,822 $1,400 Implemented
BD0269 # 04 Y:2004 04 2004 DIRECT WARMEST AIR TO COMBUSTION INTAKE $2,160 $5,500 Implemented
BD0269 # 05 Y:2004 05 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,779 $42 Not Implemented
BD0269 # 06 Y:2004 06 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,736 $0 Implemented
BD0269 # 07 Y:2004 07 2004 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $1,363 $340 Implemented
BD0269 # 08 Y:2004 08 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,601 $731 Implemented
BD0269 # 09 Y:2004 09 2004 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $1,243 $2,000 Implemented
BD0269 # 10 Y:2004 10 2004 INSTALL OCCUPANCY SENSORS $1,157 $1,200 Not Implemented
BD0269 # 11 Y:2004 11 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $680 $500 Implemented
BD0269 # 12 Y:2004 12 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $373 $368 Implemented
BD0269 # 13 Y:2004 13 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $274 $850 Not Implemented
BD0269 # 14 Y:2004 14 2004 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $236 $70 Implemented
BD0269 # 15 Y:2004 15 2004 METER WASTE WATER $587 $165 Implemented
BD0269 # 16 Y:2004 16 2004 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $423 $746 Implemented
NC0280 # 01 Y:2004 01 2004 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $18,958 $500 Not Implemented
NC0280 # 02 Y:2004 02 2004 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $69,623 $360,000 Not Implemented
NC0280 # 03 Y:2004 03 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $109,628 $121,591 n/a
NC0280 # 04 Y:2004 04 2004 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $24,049 $79,415 n/a
NC0280 # 05 Y:2004 05 2004 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $19,146 $6,453 Not Implemented