Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsNAICS | 33131 | Alumina and Aluminum Production and Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0438 # 02 Y:2011 | 02 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,986 | $25,242 | Not Implemented |
WV0438 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $39,104 | $107,167 | Not Implemented |
WV0438 # 11 Y:2011 | 11 | 2011 | INSTALL SET-BACK TIMERS | $927 | $617 | Not Implemented |
WV0438 # 10 Y:2011 | 10 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,332 | $359 | Implemented |
WV0438 # 09 Y:2011 | 09 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,774 | $648 | Not Implemented |
WV0438 # 08 Y:2011 | 08 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $8,588 | $629 | Implemented |
WV0438 # 07 Y:2011 | 07 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,963 | $2,000 | Implemented |
WV0438 # 06 Y:2011 | 06 | 2011 | INSULATE BARE EQUIPMENT | $10,092 | $2,424 | Not Implemented |
WV0438 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,808 | $24,313 | Implemented |
WV0438 # 04 Y:2011 | 04 | 2011 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $14,539 | $4,000 | Implemented |
WV0438 # 03 Y:2011 | 03 | 2011 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $23,750 | $68,377 | Not Implemented |
UF0448 # 12 Y:2011 | 12 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $515,044 | $294,885 | Not Implemented |
UF0448 # 11 Y:2011 | 11 | 2011 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $291 | $1,730 | Not Implemented |
UF0448 # 10 Y:2011 | 10 | 2011 | INSULATE BARE EQUIPMENT | $5,708 | $4,205 | Not Implemented |
UF0448 # 09 Y:2011 | 09 | 2011 | USE COMPRESSOR AIR FILTERS | $7,367 | $1,634 | Not Implemented |
UF0448 # 08 Y:2011 | 08 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,397 | $9,355 | Implemented |
UF0448 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $3,518 | $2,040 | Implemented |
UF0448 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $3,138 | $1,469 | Not Implemented |
UF0448 # 05 Y:2011 | 05 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,034 | $1,627 | Not Implemented |
UF0448 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,395 | $1,400 | Not Implemented |
UF0448 # 03 Y:2011 | 03 | 2011 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $20,728 | $4,066 | Not Implemented |
UF0448 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,949 | $11,511 | Not Implemented |
UF0448 # 01 Y:2011 | 01 | 2011 | INSTALL SKYLIGHTS | $29,002 | $67,157 | Not Implemented |