Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,084
matching recommendationsNAICS | 3315 | Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0280 # 02 Y:2009 | 02 | 2009 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $7,999 | $0 | Implemented |
SU0280 # 03 Y:2009 | 03 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,445 | $0 | Implemented |
SU0280 # 04 Y:2009 | 04 | 2009 | USE SYNTHETIC LUBRICANT | $1,438 | $0 | Not Implemented |
SU0280 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,497 | $378 | Implemented |
SU0280 # 06 Y:2009 | 06 | 2009 | INSTALL OCCUPANCY SENSORS | $4,873 | $1,477 | Implemented |
SU0280 # 07 Y:2009 | 07 | 2009 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,497 | $3,768 | Implemented |
SU0280 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $344 | $405 | Not Implemented |
SU0280 # 09 Y:2009 | 09 | 2009 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $47,225 | $73,508 | Not Implemented |
SU0280 # 10 Y:2009 | 10 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $644 | $1,009 | Not Implemented |
SU0280 # 11 Y:2009 | 11 | 2009 | OPTIMIZE PLANT POWER FACTOR | $2,725 | $7,949 | Implemented |
SD0412 # 01 Y:2009 | 01 | 2009 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $41,473 | $350,000 | Not Implemented |
SD0412 # 02 Y:2009 | 02 | 2009 | ADJUST BURNERS FOR EFFICIENT OPERATION | $21,022 | $10,000 | Not Implemented |
SD0412 # 03 Y:2009 | 03 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,233 | $13,039 | Implemented |
SD0412 # 04 Y:2009 | 04 | 2009 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $13,730 | $70,000 | Not Implemented |
SD0412 # 05 Y:2009 | 05 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,333 | $0 | Implemented |
SD0412 # 06 Y:2009 | 06 | 2009 | INSTALL SKYLIGHTS | $3,365 | $9,170 | Implemented |
BD0351 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,834 | $48,839 | Not Implemented |
BD0351 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $2,088 | $2,250 | Not Implemented |
BD0351 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $412 | $425 | Not Implemented |
BD0351 # 04 Y:2008 | 04 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,907 | $1,500 | Not Implemented |
BD0351 # 05 Y:2008 | 05 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $62,988 | $47,700 | Not Implemented |
BD0351 # 06 Y:2008 | 06 | 2008 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $9,722 | $25,200 | Not Implemented |
BD0351 # 07 Y:2008 | 07 | 2008 | MODIFY STARTUP/SHUTDOWN TIMES | $84,567 | $63,000 | Not Implemented |
UA0027 # 01 Y:2008 | 01 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,165 | $1,644 | Implemented |
UA0027 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $252 | $2,679 | Not Implemented |