Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
241
matching recommendationsNAICS | 331513 | Steel Foundries (except Investment) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0878 # 02 Y:2013 | 02 | 2013 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,314 | $9,180 | Implemented |
UD0878 # 03 Y:2013 | 03 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,934 | $0 | Not Implemented |
UD0878 # 04 Y:2013 | 04 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,749 | $19,400 | Not Implemented |
UD0878 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,303 | $1,000 | Implemented |
UD0878 # 06 Y:2013 | 06 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,575 | $15,000 | Implemented |
UD0878 # 07 Y:2013 | 07 | 2013 | MINIMIZE WATER USAGE | $21,594 | $4,000 | Not Implemented |
UD0878 # 08 Y:2013 | 08 | 2013 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,800 | $2,000 | Not Implemented |
UD0878 # 09 Y:2013 | 09 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $20,903 | $15,000 | Not Implemented |
LE0354 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,024 | $8,775 | Not Implemented |
LE0354 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,607 | $4,575 | Not Implemented |
LE0354 # 03 Y:2013 | 03 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,533 | $21 | Implemented |
LE0354 # 04 Y:2013 | 04 | 2013 | INSULATE BARE EQUIPMENT | $459 | $42 | Implemented |
UD0861 # 01 Y:2012 | 01 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,708 | $0 | Implemented |
UD0861 # 02 Y:2012 | 02 | 2012 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $8,039 | $10,000 | Not Implemented |
UD0861 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,507 | $3,496 | Not Implemented |
UD0861 # 04 Y:2012 | 04 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,025 | $0 | Implemented |
UD0861 # 05 Y:2012 | 05 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $1,371 | $3,440 | Implemented |
UD0861 # 06 Y:2012 | 06 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,167 | $0 | Implemented |
UD0861 # 07 Y:2012 | 07 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $14,934 | $2,000 | Implemented |
UD0861 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $701 | $1,000 | Implemented |
UD0861 # 09 Y:2012 | 09 | 2012 | COVER OPEN TANKS | $6,896 | $0 | Implemented |
UD0861 # 10 Y:2012 | 10 | 2012 | COVER OPEN TANKS | $6,786 | $0 | Implemented |
UD0861 # 11 Y:2012 | 11 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,234 | $11,000 | Not Implemented |
UD0861 # 12 Y:2012 | 12 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,453 | $10,000 | Not Implemented |
UD0861 # 13 Y:2012 | 13 | 2012 | COVER OPEN TANKS | $4,954 | $0 | Implemented |