Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,517
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0243 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $186 | $428 | Implemented |
SU0243 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $382 | $912 | Implemented |
SU0243 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $39,436 | $104,800 | Not Implemented |
SU0243 # 11 Y:2006 | 11 | 2006 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $23,312 | $73,075 | Not Implemented |
TA0124 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,410 | $625 | Implemented |
TA0124 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,256 | $0 | Implemented |
TA0124 # 03 Y:2006 | 03 | 2006 | INSTALL OCCUPANCY SENSORS | $90 | $135 | Implemented |
TA0124 # 04 Y:2006 | 04 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $20,890 | $0 | Implemented |
TA0124 # 05 Y:2006 | 05 | 2006 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,050 | $6,882 | Not Implemented |
TA0124 # 06 Y:2006 | 06 | 2006 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,664 | $832 | Implemented |
TA0121 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,494 | $247 | Not Implemented |
TA0121 # 02 Y:2006 | 02 | 2006 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $160 | $300 | Not Implemented |
TA0121 # 03 Y:2006 | 03 | 2006 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,838 | $2,419 | Not Implemented |
TA0121 # 04 Y:2006 | 04 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,770 | $1,770 | Not Implemented |
UM0313 # 01 Y:2006 | 01 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $24,823 | $0 | Implemented |
UM0313 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,498 | $9,857 | Not Implemented |
UM0313 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,655 | $225 | Implemented |
UM0313 # 04 Y:2006 | 04 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,007 | $1,100 | Not Implemented |
UM0313 # 05 Y:2006 | 05 | 2006 | INSULATE BARE EQUIPMENT | $431 | $323 | Not Implemented |
UM0313 # 06 Y:2006 | 06 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $56 | $0 | Not Implemented |
MS0304 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $289,291 | $222,009 | Implemented |
MS0304 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $118,243 | $1,820 | Implemented |
MS0304 # 03 Y:2006 | 03 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,366 | $16,063 | Implemented |
MS0304 # 04 Y:2006 | 04 | 2006 | USE SYNTHETIC LUBRICANT | $7,010 | $153 | Implemented |
TA0120 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,165 | $200 | Not Implemented |