Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
321
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0421 # 05 Y:2009 | 05 | 2009 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $3,680 | $2,262 | Not Implemented |
UF0421 # 04 Y:2009 | 04 | 2009 | INSTALL SKYLIGHTS | $1,691 | $11,790 | Not Implemented |
UF0421 # 03 Y:2009 | 03 | 2009 | INSTALL COMMON HEADER ON COMPRESSORS | $2,293 | $0 | Implemented |
UF0421 # 02 Y:2009 | 02 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $31,204 | $62,181 | Not Implemented |
UF0421 # 01 Y:2009 | 01 | 2009 | INSTALL OCCUPANCY SENSORS | $4,519 | $1,280 | Not Implemented |
MI0174 # 01 Y:2008 | 01 | 2008 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $214,998 | $360,000 | Not Implemented |
MI0174 # 02 Y:2008 | 02 | 2008 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $32,694 | $2,000 | Implemented |
MI0174 # 03 Y:2008 | 03 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $21,544 | $40 | Implemented |
MI0174 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,041 | $1,210 | Implemented |
MI0174 # 05 Y:2008 | 05 | 2008 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $10,087 | $13,200 | Not Implemented |
MI0174 # 06 Y:2008 | 06 | 2008 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $4,075 | $322 | Implemented |
UF0386 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,441 | $4,440 | Not Implemented |
UF0386 # 02 Y:2006 | 02 | 2006 | ADD AREA LIGHTING SWITCHES | $5,721 | $13,094 | Not Implemented |
UF0386 # 03 Y:2006 | 03 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,878 | $0 | Not Implemented |
UF0386 # 04 Y:2006 | 04 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,880 | $56 | Not Implemented |
UF0386 # 05 Y:2006 | 05 | 2006 | INSTALL OCCUPANCY SENSORS | $1,101 | $1,703 | Not Implemented |
UF0386 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,727 | $1,457 | Not Implemented |
UF0386 # 07 Y:2006 | 07 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $811 | $0 | Not Implemented |
UF0386 # 08 Y:2006 | 08 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $711 | $0 | Not Implemented |
UF0386 # 09 Y:2006 | 09 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $212 | $0 | Not Implemented |
UF0386 # 10 Y:2006 | 10 | 2006 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $4,883 | $846 | Not Implemented |
UF0386 # 11 Y:2006 | 11 | 2006 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,887 | $24,500 | Not Implemented |
MI0131 # 01 Y:2006 | 01 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $42,001 | $40,224 | Implemented |
MI0131 # 02 Y:2006 | 02 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $41,642 | $6,538 | Implemented |
MI0131 # 03 Y:2006 | 03 | 2006 | $16,391 | $29,320 | Implemented |