Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
45
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1515 # 12 Y:2015 | 12 | 2015 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $4,162 | $4,332 | Not Implemented |
UK1515 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,141 | $3,760 | Implemented |
UK1515 # 10 Y:2015 | 10 | 2015 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $838 | $0 | Implemented |
UK1515 # 11 Y:2015 | 11 | 2015 | ELIMINATE/REDUCE AN OPERATION | $144,648 | $0 | Implemented |
UK1515 # 13 Y:2015 | 13 | 2015 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $976 | $854 | Implemented |
UK1515 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,346 | $11,375 | Implemented |
UK1515 # 06 Y:2015 | 06 | 2015 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $426 | $0 | Not Implemented |
UK1515 # 08 Y:2015 | 08 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,702 | $1,700 | Implemented |
UK1515 # 09 Y:2015 | 09 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $15,940 | $12,750 | Not Implemented |
UK1515 # 07 Y:2015 | 07 | 2015 | CLEAN CONDENSER TUBES | $575 | $500 | Implemented |
UK1515 # 03 Y:2015 | 03 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $597 | $0 | Implemented |
UK1515 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,105 | $1,169 | Implemented |
UK1515 # 05 Y:2015 | 05 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,215 | $0 | Implemented |
UK1515 # 14 Y:2015 | 14 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $10,160 | $5,539 | Implemented |
UK1513 # 01 Y:2015 | 01 | 2015 | INSTALL OCCUPANCY SENSORS | $1,818 | $4,620 | Implemented |
UK1513 # 12 Y:2015 | 12 | 2015 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $970 | $540 | Not Implemented |
UK1513 # 11 Y:2015 | 11 | 2015 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $13,743 | $10,894 | Implemented |
UK1513 # 10 Y:2015 | 10 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,629 | $4,340 | Implemented |
UK1513 # 09 Y:2015 | 09 | 2015 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $3,308 | $8,000 | Not Implemented |
UK1513 # 08 Y:2015 | 08 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,883 | $1,750 | Implemented |
UK1513 # 07 Y:2015 | 07 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,363 | $440 | Implemented |
UK1513 # 06 Y:2015 | 06 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $12,766 | $14,063 | Implemented |
UK1513 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,440 | $1,500 | Implemented |
UK1513 # 04 Y:2015 | 04 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,053 | $0 | Implemented |
UK1513 # 03 Y:2015 | 03 | 2015 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $284 | $0 | Implemented |