Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,176
matching recommendationsNAICS | 3323 | Architectural and Structural Metals Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0980 # 12 Y:2018 | 12 | 2018 | INSTALL OCCUPANCY SENSORS | $1,285 | $700 | Not Implemented |
WM0116 # 01 Y:2018 | 01 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $14,609 | $72,000 | Not Implemented |
WM0116 # 02 Y:2018 | 02 | 2018 | USE PHOTOCELL CONTROLS | $3,191 | $10,230 | Not Implemented |
WM0116 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,895 | $14,722 | Implemented |
WM0116 # 04 Y:2018 | 04 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,112 | $14,000 | Not Implemented |
WM0116 # 05 Y:2018 | 05 | 2018 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $3,017 | $3,000 | Not Implemented |
WM0116 # 06 Y:2018 | 06 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,729 | $1,833 | Implemented |
WM0116 # 07 Y:2018 | 07 | 2018 | REPAIR OR REPLACE STEAM TRAPS | $1,678 | $3,960 | Implemented |
WM0116 # 08 Y:2018 | 08 | 2018 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,597 | $3,400 | Implemented |
WM0116 # 09 Y:2018 | 09 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,233 | $3,124 | Not Implemented |
WM0116 # 10 Y:2018 | 10 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $395 | $720 | Implemented |
AM0741 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,660 | $24,700 | Not Implemented |
AM0741 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,260 | $500 | Implemented |
AM0741 # 03 Y:2017 | 03 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,210 | $10 | Implemented |
AM0741 # 04 Y:2017 | 04 | 2017 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $560 | $160 | Implemented |
OR0693 # 01 Y:2017 | 01 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,809 | $500 | Not Implemented |
OR0693 # 02 Y:2017 | 02 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,614 | $2,800 | Not Implemented |
OR0693 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $27,216 | $28,216 | Not Implemented |
OR0693 # 04 Y:2017 | 04 | 2017 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $45,260 | $144,180 | Not Implemented |
OR0692 # 01 Y:2017 | 01 | 2017 | REDUCE FLUID FLOW RATES | $26,801 | $7,395 | Not Implemented |
OR0692 # 02 Y:2017 | 02 | 2017 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,636 | $3,060 | Not Implemented |
OR0692 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,299 | $3,670 | Not Implemented |
CL1703 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,383 | $20,450 | Implemented |
CL1703 # 02 Y:2017 | 02 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $28,843 | $0 | Implemented |
CL1703 # 03 Y:2017 | 03 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $14,735 | $0 | Not Implemented |