Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
110
matching recommendationsNAICS | 33232 | Ornamental and Architectural Metal Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0614 # 01 Y:2012 | 01 | 2012 | OPTIMIZE PLANT POWER FACTOR | $12,400 | $24,400 | Implemented |
AM0614 # 02 Y:2012 | 02 | 2012 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $51,500 | $1,500 | Implemented |
AM0614 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,300 | $15 | Implemented |
AM0614 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,800 | $700 | Implemented |
AM0614 # 05 Y:2012 | 05 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,500 | $5,370 | Implemented |
AM0614 # 06 Y:2012 | 06 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $700 | $780 | Implemented |
AM0614 # 07 Y:2012 | 07 | 2012 | USE SYNTHETIC LUBRICANT | $490 | $0 | Implemented |
AM0614 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $500 | $280 | Not Implemented |
AM0614 # 09 Y:2012 | 09 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $30 | $630 | Not Implemented |
AM0556 # 01 Y:2009 | 01 | 2009 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $110,800 | $325,000 | Not Implemented |
AM0556 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,000 | $36,100 | Implemented |
AM0556 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,800 | $1,000 | Implemented |
AM0556 # 04 Y:2009 | 04 | 2009 | OPTIMIZE PLANT POWER FACTOR | $6,510 | $21,230 | Not Implemented |
AM0556 # 05 Y:2009 | 05 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,650 | $11,713 | Implemented |
AM0556 # 06 Y:2009 | 06 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,980 | $3,900 | Not Implemented |
AM0556 # 07 Y:2009 | 07 | 2009 | INSTALL SKYLIGHTS | $3,200 | $4,140 | Not Implemented |
AM0556 # 08 Y:2009 | 08 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,290 | $1,000 | Implemented |
AM0556 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,730 | $8,200 | Implemented |
AM0556 # 10 Y:2009 | 10 | 2009 | USE SYNTHETIC LUBRICANT | $1,405 | $0 | Not Implemented |
AM0556 # 11 Y:2009 | 11 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $105 | $82 | Not Implemented |
TA0119 # 01 Y:2006 | 01 | 2006 | OPTIMIZE PLANT POWER FACTOR | $14,150 | $25,000 | Implemented |
TA0119 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,785 | $385 | Implemented |
TA0119 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $480 | $0 | Implemented |
TA0119 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $370 | $370 | Implemented |
TA0119 # 05 Y:2006 | 05 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $60 | $0 | Implemented |