IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

574

matching recommendations
Reset
NAICS 332322 Sheet Metal Work Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0839 # 02 Y:2007 02 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $22,858 $49,525 Implemented
GT0839 # 03 Y:2007 03 2007 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $4,603 $5,050 Not Implemented
GT0839 # 04 Y:2007 04 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $14,992 $1,000 Implemented
GT0839 # 05 Y:2007 05 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,582 $0 Implemented
TA0119 # 01 Y:2006 01 2006 OPTIMIZE PLANT POWER FACTOR $14,150 $25,000 Implemented
TA0119 # 02 Y:2006 02 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,785 $385 Implemented
TA0119 # 03 Y:2006 03 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $480 $0 Implemented
TA0119 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $370 $370 Implemented
TA0119 # 05 Y:2006 05 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $60 $0 Implemented
TA0113 # 01 Y:2006 01 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $55,045 $24,738 Implemented
TA0113 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $540 $370 Not Implemented
TA0113 # 03 Y:2006 03 2006 INSULATE BARE EQUIPMENT $12,153 $1,123 Not Implemented
TA0113 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $232 $340 Not Implemented
TA0113 # 05 Y:2006 05 2006 OPTIMIZE PLANT POWER FACTOR $12,697 $25,000 Implemented
UD0729 # 01 Y:2005 01 2005 DEVELOP STANDARD OPERATING PROCEDURES $256,000 $110,000 Not Implemented
UD0729 # 02 Y:2005 02 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $113,219 $13,700 Not Implemented
UD0729 # 03 Y:2005 03 2005 USE PHOTOCELL CONTROLS $99,594 $0 Not Implemented
UD0729 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $55,514 $0 Not Implemented
UD0729 # 05 Y:2005 05 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $19,115 $0 Implemented
UD0729 # 06 Y:2005 06 2005 UPGRADE CONTROLS ON COMPRESSORS $11,374 $1,725 Implemented
UD0729 # 07 Y:2005 07 2005 DISCONNECT BALLASTS $8,190 $2,250 Implemented
UD0729 # 08 Y:2005 08 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,187 $4,650 Not Implemented
UD0729 # 09 Y:2005 09 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,422 $0 Not Implemented
UD0729 # 10 Y:2005 10 2005 INSULATE BARE EQUIPMENT $487 $0 Implemented
UF0363 # 01 Y:2005 01 2005 INSTALL SKYLIGHTS $13,867 $51,456 Not Implemented