Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
574
matching recommendationsNAICS | 332322 | Sheet Metal Work Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0839 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,858 | $49,525 | Implemented |
GT0839 # 03 Y:2007 | 03 | 2007 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $4,603 | $5,050 | Not Implemented |
GT0839 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,992 | $1,000 | Implemented |
GT0839 # 05 Y:2007 | 05 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,582 | $0 | Implemented |
TA0119 # 01 Y:2006 | 01 | 2006 | OPTIMIZE PLANT POWER FACTOR | $14,150 | $25,000 | Implemented |
TA0119 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,785 | $385 | Implemented |
TA0119 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $480 | $0 | Implemented |
TA0119 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $370 | $370 | Implemented |
TA0119 # 05 Y:2006 | 05 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $60 | $0 | Implemented |
TA0113 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $55,045 | $24,738 | Implemented |
TA0113 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $540 | $370 | Not Implemented |
TA0113 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $12,153 | $1,123 | Not Implemented |
TA0113 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $232 | $340 | Not Implemented |
TA0113 # 05 Y:2006 | 05 | 2006 | OPTIMIZE PLANT POWER FACTOR | $12,697 | $25,000 | Implemented |
UD0729 # 01 Y:2005 | 01 | 2005 | DEVELOP STANDARD OPERATING PROCEDURES | $256,000 | $110,000 | Not Implemented |
UD0729 # 02 Y:2005 | 02 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $113,219 | $13,700 | Not Implemented |
UD0729 # 03 Y:2005 | 03 | 2005 | USE PHOTOCELL CONTROLS | $99,594 | $0 | Not Implemented |
UD0729 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $55,514 | $0 | Not Implemented |
UD0729 # 05 Y:2005 | 05 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $19,115 | $0 | Implemented |
UD0729 # 06 Y:2005 | 06 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $11,374 | $1,725 | Implemented |
UD0729 # 07 Y:2005 | 07 | 2005 | DISCONNECT BALLASTS | $8,190 | $2,250 | Implemented |
UD0729 # 08 Y:2005 | 08 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,187 | $4,650 | Not Implemented |
UD0729 # 09 Y:2005 | 09 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,422 | $0 | Not Implemented |
UD0729 # 10 Y:2005 | 10 | 2005 | INSULATE BARE EQUIPMENT | $487 | $0 | Implemented |
UF0363 # 01 Y:2005 | 01 | 2005 | INSTALL SKYLIGHTS | $13,867 | $51,456 | Not Implemented |