matching recommendationsNAICS | 33242 | Metal Tank (Heavy Gauge) Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0010 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,004 | $14,292 | Implemented |
UA0010 # 03 Y:2007 | 03 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $742 | $0 | Not Implemented |
UA0010 # 04 Y:2007 | 04 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $426 | $590 | Implemented |
UA0010 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,616 | $700 | Implemented |
UA0010 # 06 Y:2007 | 06 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $96 | $528 | Implemented |
UA0010 # 07 Y:2007 | 07 | 2007 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $933 | $0 | Implemented |
UA0010 # 08 Y:2007 | 08 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $155 | $320 | Implemented |
UA0010 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,084 | $70,481 | Implemented |
WV0358 # 14 Y:2007 | 14 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $410 | $22 | Not Implemented |
WV0358 # 13 Y:2007 | 13 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $432 | $119 | Not Implemented |
WV0358 # 12 Y:2007 | 12 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $468 | $78 | Implemented |
WV0358 # 11 Y:2007 | 11 | 2007 | INSTALL OCCUPANCY SENSORS | $679 | $2,103 | Implemented |
WV0358 # 10 Y:2007 | 10 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $998 | $1,555 | Implemented |
WV0358 # 09 Y:2007 | 09 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $1,016 | $555 | Implemented |
WV0358 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,029 | $0 | Implemented |
WV0358 # 07 Y:2007 | 07 | 2007 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,651 | $1,000 | Implemented |
WV0358 # 06 Y:2007 | 06 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,908 | $5,830 | Not Implemented |
WV0358 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,775 | $8,600 | Implemented |
WV0358 # 04 Y:2007 | 04 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $24,675 | $15,300 | Implemented |
WV0358 # 03 Y:2007 | 03 | 2007 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $20,287 | $6,050 | Implemented |
WV0358 # 02 Y:2007 | 02 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $27,409 | $34,100 | Not Implemented |
WV0358 # 01 Y:2007 | 01 | 2007 | IMPROVE COMBUSTION CONTROL CAPABILITY | $91,739 | $34,400 | Not Implemented |