Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
65
matching recommendationsNAICS | 3331 | Agriculture, Construction, and Mining Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0111 # 06 Y:2005 | 06 | 2005 | DISCONNECT BALLASTS | $1,660 | $140 | Not Implemented |
TA0111 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,913 | $400 | Not Implemented |
TA0111 # 03 Y:2005 | 03 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $44,045 | $20,000 | Not Implemented |
TA0111 # 01 Y:2005 | 01 | 2005 | CLEAR AND RENT EXISTING SPACE | $225,000 | $2,250 | Not Implemented |
TA0111 # 02 Y:2005 | 02 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $51,150 | $0 | Not Implemented |
TA0111 # 05 Y:2005 | 05 | 2005 | OPTIMIZE PLANT POWER FACTOR | $2,750 | $5,500 | Not Implemented |
TA0111 # 07 Y:2005 | 07 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,370 | $10 | Not Implemented |
CO0577 # 01 Y:2005 | 01 | 2005 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $141,620 | $513,000 | Not Implemented |
CO0577 # 07 Y:2005 | 07 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $810 | $3,070 | Not Implemented |
CO0577 # 03 Y:2005 | 03 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $89,400 | $41,000 | Implemented |
CO0577 # 04 Y:2005 | 04 | 2005 | MODIFY WORKLOAD | $48,020 | $360 | Implemented |
CO0577 # 05 Y:2005 | 05 | 2005 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $3,420 | $6,000 | Implemented |
CO0577 # 02 Y:2005 | 02 | 2005 | OPTIMIZE PLANT POWER FACTOR | $135,890 | $303,800 | Implemented |
CO0577 # 06 Y:2005 | 06 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $270 | $340 | Implemented |
CO0577 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $38,530 | $150,890 | Not Implemented |
LL0228 # 05 Y:2005 | 05 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $16,509 | $0 | Not Implemented |
LL0228 # 06 Y:2005 | 06 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $14,813 | $0 | Not Implemented |
LL0228 # 04 Y:2005 | 04 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $19,616 | $0 | Not Implemented |
LL0228 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,872 | $0 | Not Implemented |
LL0228 # 09 Y:2005 | 09 | 2005 | USE PHOTOCELL CONTROLS | $870 | $0 | Not Implemented |
LL0228 # 10 Y:2005 | 10 | 2005 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $7,627 | $0 | Not Implemented |
LL0228 # 11 Y:2005 | 11 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $106,500 | $20,000 | Implemented |
LL0228 # 12 Y:2005 | 12 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $80,610 | $20,000 | Implemented |
LL0228 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $47,819 | $22,000 | Implemented |
LL0228 # 02 Y:2005 | 02 | 2005 | USE PHOTOCELL CONTROLS | $55,019 | $0 | Not Implemented |