Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
59
matching recommendationsNAICS | 33311 | Agricultural Implement Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0454 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,088 | $7,920 | Not Implemented |
WV0454 # 04 Y:2012 | 04 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $3,789 | $19,607 | Not Implemented |
WV0454 # 07 Y:2012 | 07 | 2012 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,686 | $2,767 | Not Implemented |
WV0454 # 10 Y:2012 | 10 | 2012 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $531 | $1,000 | Implemented |
WV0454 # 06 Y:2012 | 06 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $1,836 | $775 | Implemented |
WV0454 # 08 Y:2012 | 08 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,449 | $468 | Not Implemented |
WV0454 # 11 Y:2012 | 11 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $424 | $50 | Implemented |
WV0454 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,331 | $11,667 | Not Implemented |
WV0454 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,085 | $108,401 | Not Implemented |
WV0454 # 09 Y:2012 | 09 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,183 | $2,711 | Not Implemented |
WV0454 # 03 Y:2012 | 03 | 2012 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $4,992 | $13,611 | Not Implemented |
UD0862 # 11 Y:2012 | 11 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,020 | $2,000 | Not Implemented |
UD0862 # 10 Y:2012 | 10 | 2012 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $2,963 | $10,000 | Not Implemented |
UD0862 # 09 Y:2012 | 09 | 2012 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $3,985 | $10,000 | Not Implemented |
UD0862 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,513 | $67,068 | Not Implemented |
UD0862 # 08 Y:2012 | 08 | 2012 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,095 | $3,000 | Not Implemented |
UD0862 # 07 Y:2012 | 07 | 2012 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $14,974 | $30,000 | Not Implemented |
UD0862 # 06 Y:2012 | 06 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,687 | $11,000 | Not Implemented |
UD0862 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,711 | $410 | Not Implemented |
UD0862 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,018 | $1,000 | Not Implemented |
UD0862 # 01 Y:2012 | 01 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,703 | $0 | Not Implemented |
UD0862 # 03 Y:2012 | 03 | 2012 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,270 | $11,275 | Not Implemented |
UD0765 # 11 Y:2007 | 11 | 2007 | INSTALL SKYLIGHTS | $354 | $1,083 | Implemented |
UD0765 # 02 Y:2007 | 02 | 2007 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $4,626 | $17,500 | Not Implemented |
UD0765 # 01 Y:2007 | 01 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $9,128 | $3,450 | Implemented |