Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
749
matching recommendationsNAICS | 3332 | Industrial Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0592 # 01 Y:2020 | 01 | 2020 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,201 | $9,500 | Implemented |
WV0592 # 02 Y:2020 | 02 | 2020 | RECYCLE WHITE WATER | $6,078 | $6,252 | Not Implemented |
WV0592 # 03 Y:2020 | 03 | 2020 | INSTALL OCCUPANCY SENSORS | $4,217 | $9,054 | Implemented |
WV0592 # 04 Y:2020 | 04 | 2020 | MINIMIZE WATER USAGE | $3,145 | $2,100 | Implemented |
WV0592 # 05 Y:2020 | 05 | 2020 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,832 | $4,720 | Not Implemented |
WV0592 # 06 Y:2020 | 06 | 2020 | INSTALL SET-BACK TIMERS | $1,823 | $222 | Implemented |
WV0592 # 07 Y:2020 | 07 | 2020 | UPGRADE CONTROLS ON COMPRESSORS | $1,361 | $3,757 | Not Implemented |
WV0592 # 08 Y:2020 | 08 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $964 | $3,240 | Implemented |
WV0592 # 09 Y:2020 | 09 | 2020 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $829 | $3,850 | Not Implemented |
WV0592 # 10 Y:2020 | 10 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $723 | $1,312 | Implemented |
WV0592 # 11 Y:2020 | 11 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $397 | $36 | Implemented |
WV0592 # 12 Y:2020 | 12 | 2020 | DEVELOP A REPAIR/REPLACE POLICY | $372 | $303 | Implemented |
WV0592 # 13 Y:2020 | 13 | 2020 | INSULATE BARE EQUIPMENT | $157 | $742 | Implemented |
WV0592 # 14 Y:2020 | 14 | 2020 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $47 | $250 | Not Implemented |
MZ0275 # 03 Y:2020 | 03 | 2020 | INSTALL OCCUPANCY SENSORS | $5,169 | $10,500 | Not Implemented |
MZ0275 # 04 Y:2020 | 04 | 2020 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,201 | $3,250 | Not Implemented |
MZ0275 # 05 Y:2020 | 05 | 2020 | USE PHOTOCELL CONTROLS | $1,385 | $1,440 | Not Implemented |
MZ0275 # 06 Y:2020 | 06 | 2020 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,072 | $2,400 | Not Implemented |
MZ0275 # 01 Y:2020 | 01 | 2020 | TURN OFF EQUIPMENT WHEN NOT IN USE | $12,533 | $24,500 | Not Implemented |
MZ0275 # 02 Y:2020 | 02 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,790 | $7,081 | Not Implemented |
GT0942 # 01 Y:2020 | 01 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $20,227 | $1,450 | Implemented |
GT0942 # 02 Y:2020 | 02 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,618 | $2,500 | Implemented |
GT0942 # 03 Y:2020 | 03 | 2020 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $14,945 | $4,781 | Not Implemented |
GT0942 # 04 Y:2020 | 04 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $50,179 | $71,763 | Not Implemented |
GT0942 # 05 Y:2020 | 05 | 2020 | MINIMIZE WATER USAGE | $3,202 | $5,700 | Not Implemented |